Optics and Precision Engineering, Volume. 29, Issue 10, 2363(2021)

Optimized design model of novel diagonal micropolarizer arrays

Jia HAO1...2,3, Yan WANG1,2,3, Kui ZHOU1,2,3, Xiao-chang YU1,2,3, and Yi-ting YU1,23,* |Show fewer author(s)
Author Affiliations
  • 1Research & Development Institute of Northwestern Polytechnical University in Shenzhen, Shenzhen58057, China
  • 2Key Laboratory of Micro/Nano Systems for Aerospace, Ministry of Education, Northwestern Polytechnical University, Xi’an71007, China
  • 3Key Laboratory of Micro and Nano Electro-Mechanical Systems of Shaanxi Province, Northwestern Polytechnical University, Xi’an710072, China
  • show less
    Figures & Tables(12)
    Schematic diagram of core optical elements for DoFP polarization imaging system
    Eight MPA patterns
    Discrete Fourier Transform (DFT) spectra of different MPA pattens
    Expression formulas of micropolarizer at different positions
    Reconstruction flowchart of Stokes parameters,DoLP and AoP images
    Visual band polarization information acquisition system
    Optical properties of polarizers in visible band
    Original intensity image of real vehicle target under shade of trees
    Reconstructed DoLP images of different MPA patterns on same testing scene. (a1) 2×2, (b1) 2×4, (c1) 2×3, (d1) 2×7, (e1) 2×2×2, (f1) 3×3, (g1) 5×5, (h1) 7×7, and (i1) ground-truth; (a2)-(i2) the enlarged views of white rectangular regions of the (a1)-(i1)
    Convergent curves of PSNR on testing scene with different MPA patterns
    • Table 1. Design parameters for eight types of MPA pattern

      View table
      View in Article

      Table 1. Design parameters for eight types of MPA pattern

      TypeOriginSizeabcN
      NChun182×2---1
      LeMaster192×44211
      Alenin202×331.511
      Alenin202×773.521
      Alenin202×2×22112
      Diag N×NThis work3×33111
      This work5×55221
      This work7×77331
    • Table 2. Comparison of evaluation index results of reconstruction images with different MPAs

      View table
      View in Article

      Table 2. Comparison of evaluation index results of reconstruction images with different MPAs

      模式RMSEPSNRSSIM
      S0S1S2DoLPS0S1S2DoLPS0S1S2DoLP
      2×20.010 30.010 80.010 90.010 639.734 339.319 639.223 039.501 80.996 10.972 80.972 40.960 4
      2×40.006 80.009 30.009 40.008 743.369 240.649 140.548 841.172 80.998 00.980 10.980 60.968 7
      2×30.006 10.010 40.010 40.009 644.226 639.657 939.693 440.333 60.998 30.975 10.979 70.965 9
      2×70.006 50.009 50.009 50.009 043.776 540.441 840.458 940.903 90.998 10.978 50.979 70.968 0
      2×2×20.005 60.005 60.005 70.005 145.032 345.030 844.883 445.922 50.998 50.990 60.989 10.985 2
      3×30.007 30.008 70.008 50.007 842.770 141.168 941.399 942.193 70.998 00.980 30.981 00.971 9
      5×50.006 20.010 50.010 50.009 744.186 739.593 039.570 440.299 50.998 30.971 20.973 70.957 4
      7×70.005 90.019 40.019 40.016 044.523 134.248 334.225 035.918 10.998 40.931 90.953 40.911 0
    Tools

    Get Citation

    Copy Citation Text

    Jia HAO, Yan WANG, Kui ZHOU, Xiao-chang YU, Yi-ting YU. Optimized design model of novel diagonal micropolarizer arrays[J]. Optics and Precision Engineering, 2021, 29(10): 2363

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Micro/Nano Technology and Fine Mechanics

    Received: Apr. 6, 2021

    Accepted: --

    Published Online: Nov. 23, 2021

    The Author Email: YU Yi-ting (yyt@nwpu.edu.cn)

    DOI:10.37188/OPE.2021.0173