Acta Optica Sinica, Volume. 21, Issue 2, 206(2001)
Tagging Procedures of Raman Excitation Plus Laser Induced Electronic Fluorescence Flow Velocimetry
The Raman excitation plus laser induced electronic fluorescence air flow velocimetry system is constructed. The second harmonics of Nd∶YAG laser and stimulated Raman scattering in O2 are employed as “tagging” laser source. The tagged line was interrogated with an ArF excimer laser. The laser-induced fluorescence images from tagged lines in O2 and air are captured by an intensity-CCD Camera. The velocity measurement of O2 jet is carried out.
Get Citation
Copy Citation Text
[in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese], [in Chinese]. Tagging Procedures of Raman Excitation Plus Laser Induced Electronic Fluorescence Flow Velocimetry[J]. Acta Optica Sinica, 2001, 21(2): 206