Laser & Optoelectronics Progress, Volume. 57, Issue 16, 161103(2020)
Influence of Detection Angle on the Quality of Pencil-Beam X-Ray Fluorescence CT
[1] Sokolov K V, Follen M, Aaron J et al. Real-time vital optical imaging of precancer using anti-epidermal growth factor receptor antibodies conjugated to gold nanoparticles[J]. Cancer Research, 63, 1999-2004(2003).
[3] Takeda T, Wu J, Huo Q et al. X-ray fluorescent CT imaging of cerebral uptake of stable-iodine perfusion agent iodoamphetamine analog IMP in mice[J]. Journal of Synchrotron Radiation, 16, 57-62(2009).
[4] Li L, Zhang S Y, Li R Z et al. Full-field fan-beam X--ray fluorescence computed tomography with a conventional X-ray tube and photon-counting detectors for fast nanoparticle bioimaging[J]. Optical Engineering, 56, 043106(2017).
[5] Manohar N, Reynoso F J, Cho S H. Technical note: a benchtop cone-beam X-ray fluorescence computed tomography (XFCT) system with a high-power X-ray source and transmission CT imaging capability[J]. Medical Physics, 45, 4652-4659(2018).
[6] Chen J Y, Zhang S Y, Fang W et al. The latest development of X-ray fluorescence computed tomography[J]. Chinese Journal of Stereology and Image Analysis, 23, 102-116(2018).
[7] Hanson A L. The calculation of scattering cross sections for polarized X-rays[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 243, 583-598(1986).
[10] Yuasa T, Akiba M, Takeda T et al. Reconstruction method for fluorescent X-ray computed tomography by least-squares method using singular value decomposition[J]. IEEE Transactions on Nuclear Science, 44, 54-62(1997).
[12] Cheong S K, Jones B L. K Siddiqi A, et al. X-ray fluorescence computed tomography (XFCT) imaging of gold nanoparticle-loaded objects using 110 kVp X-rays[J]. Physics in Medicine and Biology, 55, 647-662(2010).
[13] Vernekohl D, Ahmad M, Chinn G et al. Feasibility study of Compton cameras for X-ray fluorescence computed tomography with humans[J]. Physics in Medicine & Biology, 61, 8521-8540(2016).
Get Citation
Copy Citation Text
Zhizhen Ma, Shanghai Jiang, Binbin Luo, Shenghui Shi, Xue Zou, Bin Tang, Decao Wu, Mingfu Zhao. Influence of Detection Angle on the Quality of Pencil-Beam X-Ray Fluorescence CT[J]. Laser & Optoelectronics Progress, 2020, 57(16): 161103
Category: Imaging Systems
Received: Jan. 3, 2020
Accepted: Jan. 16, 2020
Published Online: Aug. 5, 2020
The Author Email: Jiang Shanghai (jiangshanghai@cqut.edu.cn)