High Power Laser and Particle Beams, Volume. 34, Issue 2, 026005(2022)
Measurement of environmental level X, γ dose with conversion of complete spectra without deconvolution method of MC simulation
[1] Knežević Z, Majer M, Baranowska Z, et al. Investigations into the basic properties of different passive dosimetry systems used in environmental radiation monitoring in the aftermath of a nuclear or radiological event[J]. Radiation Measurements, 146, 106615(2021).
[5] [5] Miuchi S. A new method of dose evaluation by spectrumdose conversion operat determination of the operat[R]. JAERI1209, 1971.
[8] [8] Tang Lili. Study on the techniques of γ dose determination by γ spectrum[D]. Chengdu: Chengdu University of Technology, 2010
[10] [10] Wei Lian. The measurement analysis of influence based on γ energy spectrum[D]. Harbin: Harbin Engineering University, 2013
[11] Dombrowski H. Area dose rate values derived from NaI or LaBr3 spectra[J]. Radiation Protection Dosimetry, 160, 269-276(2014).
[12] [12] Xu Shuyan. Application of Monte Carlo method in experimental nuclear physics[M]. 2nd ed. Beijing: Atomic Energy Press, 2006
Get Citation
Copy Citation Text
Lei Cao, Yaofeng Zhang, Yang Yang, Jianwei Huang, Xiaole Zhang. Measurement of environmental level X, γ dose with conversion of complete spectra without deconvolution method of MC simulation[J]. High Power Laser and Particle Beams, 2022, 34(2): 026005
Category: Monte Carlo Methods and Applications
Received: Jul. 20, 2021
Accepted: --
Published Online: Jan. 26, 2022
The Author Email: Huang Jianwei (huangjw@nim.ac.cn)