Journal of Innovative Optical Health Sciences, Volume. 14, Issue 1, 2140008(2021)

Constrained polynomial fit-based k-domain interpolation in swept-source optical coherence tomography

Tao Han, Jianrong Qiu, Di Wang, Jia Meng, Zhiyi Liu, and Zhihua Ding*
Author Affiliations
  • State Key Lab of Modern Optical Instrumentation College of Optical Science and Engineering Zhejiang University Hangzhou 310027, P. R. China
  • show less
    References(32)

    [1] [1] R. Leitgeb, C. K. Hitzenberger, A. F. Fercher, "Performance of fourier domain vs. time domain optical coherence tomography," Opt. Express 11(8), 889–894 (2003).

    [2] [2] J. F. de Boer, B. Cense, B. H. Park, M. C. Pierce, G. J. Tearney, B. E. Bouma, "Improved signal-tonoise ratio in spectral-domain compared with timedomain optical coherence tomography," Opt. Lett. 28(21), 2067–2069 (2003).

    [3] [3] W. Zhao, B. Potsaid, L. Chen, C. Doerr, H. C. Lee, T. Nielson, V. Jayaraman, A. E. Cable, E. Swanson, J. G. Fujimoto, "Cubic meter volume optical coherence tomography," Optica. 3(12), 1496–1503 (2016).

    [4] [4] N. Nguyen, Q. Liu, "The regular Fourier matrices and nonuniform fast Fourier transforms," SIAM J. Sci. Comput. 21(1), 283–293 (1999).

    [5] [5] T. Wu, Z. H. Ding, K. Wang, C. Wang, "Swept source optical coherence tomography based on nonuniform discrete Fourier transform," Chin. Opt. Lett. 7(10), 941–944 (2009).

    [6] [6] S. Z. Yang, L. W. Liu, Y. X. Chang, N. N. Zhang, K. Liu, L. Hong, B. L. Chen, Y. Zhao, R. Hu, J. L. Qu. "In vivo mice brain microcirculation monitoring based on contrast-enhanced SD-OCT," J. Innov. Opt. Health Sci. 12(1), 1950001 (2019).

    [7] [7] F. J. Xing, J. H. Lee, C. Polucha, J. Lee, "Threedimensional imaging of spatio-temporal dynamics of small blood capillary network in the cortex based on optical coherence tomography: A review," J. Innov. Opt. Health Sci. 13(1), 2030002 (2020).

    [8] [8] A. Abdurashitov, V. Tuchin, O. Semyachkina- Glushkovskaya, "Photodynamic therapy of brain tumors and novel optical coherence tomography strategies for in vivo monitoring of cerebral fluid dynamics," J. Innov. Opt. Health Sci. 13(2), 2030004 (2020).

    [9] [9] K. Zhang, U. K. Jin, "Graphics processing unit accelerated non-uniform fast Fourier transform for ultrahigh-speed, real-time Fourier-domain OCT," Opt. Express 18(22), 23472–23487 (2010).

    [10] [10] M. Wojtkowski, "High-speed optical coherence tomography: Basics and applications," Appl. Opt. 49(16), 30–61 (2010).

    [11] [11] X. Wei, A. Camino, S. H. Pi, T. T. Hormel, W. Cepurna, D. Huang, J. C. Morrison, Y. L. Jia, "Real-time cross-sectional and en face OCT angiography guiding high-quality scan acquisition," Opt. Lett. 44(6), 1431–1434 (2019).

    [12] [12] N. Uribe-Patarroyo, S. H. Kassani, M. Villiger, B. E. Bouma, "Robust wavenumber and dispersion calibration for Fourier-domain optical coherence tomography," Opt. Express 26(7), 9081–9094 (2018).

    [13] [13] Z. L. Hu, A. M. Rollins, "Fourier domain optical coherence tomography with a linear-in-wavenumber spectrometer," Opti. Lett. 32(24), 3525–3527 (2007).

    [14] [14] T. Wu, S. S. Sun, X. H. Wang, H. Y. Zhang, C. J. He, J. M. Wang, X. R. Gu, Y. W. Liu. "Optimization of linear-wavenumber spectrometer for high-resolution spectral domain optical coherence tomography," Opt. Commun. 405, 171–176 (2017).

    [15] [15] G. P. Lan, G. Q. Li, "Design of a k-space spectrometer for ultra-broad waveband spectral domain optical coherence tomography," Sci. Rep. 7, 42353 (2017).

    [16] [16] T. C. Huo, J. Zhang, J. G. Zheng, T. Y. Chen, C. M. Wang, N. Zhang, W. C. Liao, X. Zhang, P. Xue, "Linear-in-wavenumber swept laser with an acousto-optic deflector for optical coherence tomography," Opt. Lett. 39(2), 247–250 (2014).

    [17] [17] J. Xi, L. Huo, J. Li, X. Li, "Generic real-time uniform K-space sampling method for high-speed swept-source optical coherence tomography," Opt. Express. 18(9), 9511–9517 (2010).

    [18] [18] Y. Quan, Z. Y. Wang, L. P. Song, C. F. Ge, Z. Y. Lu, T. X. Yang, "Ultrafast wavenumber linear-stepswept source based on synchronous lightwave synthesized frequency sweeper," IEEE Photon. J. 11 (1), 1–8 (2019).

    [19] [19] Y. Watanabe, S. Maeno, K. Aoshima, H. Hasegawa, H. Koseki, "Real-time processing for full-range Fourier-domain optical-coherence tomography with zero-filling interpolation using multiple graphic processing units," Appl. Opt. 49(25), 4756–4762 (2010).

    [20] [20] V. Sebastien, D. Levesque, G. Lamouche, "Experimental validation of an optimized signal processing method to handle non-linearity in sweptsource optical coherence tomography," Opt. Express 18(10), 10446–10461 (2010).

    [21] [21] L. Y. Fang, S. T. Li, D. Cunefare, S. Farsiu, "Segmentation based sparse reconstruction of optical coherence tomography images," IEEE Trans. Med. Imaging 36(2), 407–421 (2016).

    [22] [22] M. Sucbei, Z. P. Chen, "Phase-stability optimization of swept-source optical coherence tomography," Biomed. Opt. Express 9(11), 5280–5295 (2018).

    [23] [23] Y. Yasuno, V. D. Madjarova, S. Makita, M. Akiba, A. Morosawa, C. Chong, T. Sakai, K.-P. Chan, M. Itoh, T. Yatagai, "Three-dimensional and highspeed swept-source optical coherence tomography for in vivo investigation of human anterior eye segments," Opt. Express 13(26), 10652–10664 (2005).

    [24] [24] T. Wu, Z. H. Ding, L. Wang, M. H. Chen, "Spectral phase based k-domain interpolation for uniform sampling in swept-source optical coherence tomography," Opt. Express 19(19), 18430–18439 (2011).

    [25] [25] Y. Z. Yan, Z. H. Ding, Y. Shen, Z. Y. Chen, C. Zhao, Y. Ni, "High-sensitive and broad-dynamic-range quantitative phase imaging with spectral domain phase microscopy," Opt. Express 21(22), 25734– 25743 (2013).

    [26] [26] M. Meissner, "Accuracy issues of discrete Hilbert transform in identification of instantaneous parameters of vibration signals," Acta Phys. Pol. A 121 (1), A164 (2012).

    [27] [27] J. R. Qiu, T. Han, Z. Y. Liu, J. Meng, Z. H. Ding, "Uniform focusing with an extended depth range and increased working distance for optical coherence tomography by an ultrathin monolith fiber probe," Opt. Lett. 45(4), 976–979 (2020).

    [28] [28] M. Wojtkowski, V. J. Srinivasan, T. H. Ko, J. G. Fujimoto, A. Kowalczyk, J. S. Duker, "Ultrahighresolution, high-speed, Fourier domain optical coherence tomography and methods for dispersion compensation," Opt. Express 12(11), 2404–2422 (2004).

    [29] [29] C. M. Wang, Y. J. You, S. N. Ai, W. X. Zhang, W. C. Liao, X. Zhang, J. C. Hsieh, N. Zhang, B. Tang, C. L. Pan, P. Xue, "Multi-frame speckle reduction in OCT using supercontinuum pumped by noise-like pulses," J. Innov. Opt. Health Sci. 12(2), 1950009 (2019).

    [30] [30] Y. Z. Yan, Z. H. Ding, L. Wang, C. Wang, Y. Shen, "High-sensitive quantitative phase imaging with averaged spectral domain phase microscopy," Opt. Commun. 303, 21–24 (2013).

    [31] [31] A. T. Zavareh, S. Hoyos, "Kalman-based real-time functional decomposition for the spectral calibration in swept source optical coherence tomography," IEEE Trans. Biomed. Circuits Syst. 14(2), 257–273 (2019).

    [32] [32] K. Wang, Z. H. Ding, "Spectral calibration in spectral domain optical coherence tomography," Chin. Opt. Lett. 6(12), 902–904 (2008).

    Tools

    Get Citation

    Copy Citation Text

    Tao Han, Jianrong Qiu, Di Wang, Jia Meng, Zhiyi Liu, Zhihua Ding. Constrained polynomial fit-based k-domain interpolation in swept-source optical coherence tomography[J]. Journal of Innovative Optical Health Sciences, 2021, 14(1): 2140008

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Nov. 12, 2020

    Accepted: Dec. 14, 2020

    Published Online: Apr. 7, 2021

    The Author Email: Ding Zhihua (zh_ding@zju.edu.cn)

    DOI:10.1142/s1793545821400083

    Topics