Permanent magnet bias positioning magnetic needle for novel fluid magnetic mass transfer

Qiang LIU1...3,*, Feiteng JIAO1, Haiwei SUNG2, Pingjuan NIU3 and Zixi WANG4 |Show fewer author(s)
Author Affiliations
  • 1Institute of Precision Electromagnetic Equipment and Advanced Measurement Technology, Beijing Institute of Petrochemical Technology, Beijing0267, China
  • 2Beijing Haiju Technology Co., Ltd Beijing100176, China
  • 3State Key Laboratory of Separation Membranes and Membrane Processes, Tiangong University, Tianjin0087, China
  • 4State Key Laboratory of Tribology, Tsinghua University, Beijing10008, China
  • show less
    Figures & Tables(18)
    Structure of positioning magnetic needle
    Schematic diagram of chip transfer process
    Magnetic needle sucks chip model
    Model of positioning magnetic needle
    Equivalent magnetic circuit
    Magnetic density of air gap on upper surface of magnetic needle
    Optimized permanent magnets height
    Optimized magnet conductor height
    Optimized magnetic needle diameter
    Optimized magnetic needle height
    Magnetic needle spacing optimization
    Optimized scheme of magnetic needle
    Magnetically dense measuring equipment
    Magnetic density on upper surface of magnetic needle
    Magnetic needle gripping chip tooling
    Chip suction fixation experiment result
    • Table 1. [in Chinese]

      View table
      View in Article

      Table 1. [in Chinese]

      参 数数值参 数数值
      磁钢长度/mm50磁针直径/mm0.1
      磁钢宽度/mm30磁针高度/mm0.5
      磁钢高度/mm4两磁针间距/mm2.5
      导磁体长度/mm50线圈线径/mm0.5
      导磁体宽度/mm30线圈匝数/匝1 000
      导磁体高度/mm0.5直流电/A0.5~1
    • Table 2. [in Chinese]

      View table
      View in Article

      Table 2. [in Chinese]

      参 数数值参 数数值
      磁钢长度/mm50磁针直径/mm0.2
      磁钢宽度/mm30磁针高度/mm0.6
      磁钢高度/mm5两磁针间距/mm2.5
      导磁体长度/mm50线圈线径/mm0.5
      导磁体宽度/mm30线圈匝数/匝1 000
      导磁体高度/mm0.3直流电/A0.5~1
    Tools

    Get Citation

    Copy Citation Text

    Qiang LIU, Feiteng JIAO, Haiwei SUNG, Pingjuan NIU, Zixi WANG. Permanent magnet bias positioning magnetic needle for novel fluid magnetic mass transfer[J]. Optics and Precision Engineering, 2024, 32(19): 2911

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Aug. 7, 2024

    Accepted: --

    Published Online: Jan. 9, 2025

    The Author Email: LIU Qiang (Liuqiangbuaa@163.com)

    DOI:10.37188/OPE.20243219.2911

    Topics