Optoelectronics Letters, Volume. 16, Issue 6, 467(2020)

Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine

Xiu-lin WANG1, Li-ping Lü2, Lu HU2, and Wen-cai HUANG2、*
Author Affiliations
  • 1Department of Physics, Jimei University, Xiamen 361021, China
  • 2Department of Electronics Engineering, Xiamen University, Xiamen 361005, China
  • show less
    References(20)

    [1] [1] U. Zabit, O. D. Bernal, S. Amin, M. F. Qureshi, A. H. Khawaja and T. Bosch, IEEE Sensor Journal 19, 11151 (2019).

    [2] [2] Y. K. Zhao, J. F. Zhou, C. C. Wang, R. Xiang, T. Z. Bi and L. Lu, Measurement 144, 381 (2019).

    [3] [3] S. H. Zhang, S. L. Zhang and Y. D. Tan, Optics Letters 41, 844 (2016).

    [4] [4] X. L. Wang, Z. Wei, R. Wang and W. C. Huang, Optoelectronics Letters 14, 161 (2018).

    [5] [5] Y. Zhao, B. F. Zhang and L. F. Han, Optics Communications 456, 124588 (2020).

    [6] [6] H. Sun, J. G. Liu and Q. Zhang, Journal of Applied Optics 55, 236 (2016).

    [7] [7] Y. H. Zhao, S. Wu, R. Xiang, Z. G. Cao, Y. Liu, H. Q. Gui, J. G. Liu, L. Lu and B. L. Yu, IEEE Photonics Journal 6, 6801211 (2014).

    [8] [8] C. Yanez, F. J. Azcona and S. Roy, Optics Express 27, 24340 (2019).

    [9] [9] Z. Duan, Y. Yu and B. Gao, Optics Communications 389, 270 (2017).

    [10] [10] L. Rovati, C. L. Di and S. Cattini, IEEE Transactions on Instrumentation and Measurement 69, 2495 (2020).

    [11] [11] K. Meigas, H. Hinrikus, R. Kattai and J. Lass, Journal of Biomedical Optics 8, 152 (2003).

    [12] [12] S. Donati and M. Norgia, IEEE Journal of Selected Topics in Quantum Electronics 20, 104 (2014).

    [13] [13] K. X. Wang, M. Cao and B. P. Liu, Journal of Russian Laser Research 41, 197 (2020).

    [14] [14] A. Arasanz, F. J. Azcona, S. Royo, A. Jha and J. Pladellorens, Optics & Laser Technology 63, 98 (2014).

    [15] [15] Y. B. Wei, W. C. Huang, Z. Wei, J. Zhang, T. An, X. L. Wang and H. Z. Xu, Optics Communications 393, 178 (2017).

    [16] [16] X. Liu and L. Xu, Neurocomputing 311, 176 (2018).

    [17] [17] T. Taimre, M. Nikolic, K. Bertling, Y. L. Lim, T. Bosch and A. D. Rakic, Advances in Optics and Photonics 7, 570 (2015).

    [18] [18] J. Y Li, H. S. Niu and Y. X. Niu, Optical Engineering 56, 050901 (2017).

    [19] [19] M. O’Rourke, Arterial Function in Health and Disease, Edinburgh: Churchill Livingstone, 133 (1982).

    [20] [20] J. Lee, D. J. Scott, M. Villarroel, G. D. Clifford, M. Saeed and R. G. Mark, Open-Access MIMIC-II Database for Intensive Care Research, Annual International Conference of the IEEE Engineering in Medicine and Biology Society, 8315 (2011).

    Tools

    Get Citation

    Copy Citation Text

    WANG Xiu-lin, Lü Li-ping, HU Lu, HUANG Wen-cai. Real-time human blood pressure measurement based on laser self-mixing interferometry with extreme learning machine[J]. Optoelectronics Letters, 2020, 16(6): 467

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Mar. 17, 2020

    Accepted: May. 30, 2020

    Published Online: Dec. 25, 2020

    The Author Email: Wen-cai HUANG (huangwc@xmu.edu.cn)

    DOI:10.1007/s11801-020-0050-x

    Topics