Acta Photonica Sinica, Volume. 53, Issue 2, 0206005(2024)

A Vector Displacement Measurement Sensing Device Based on Fiber Bragg Grating and Its Experimental Study

Yong ZHENG1, Jie YU2、*, Hongkai CHEN3, and Xing YI4
Author Affiliations
  • 1College of River and Ocean Engineering,Chongqing Jiaotong University,Chongqing 400074,China
  • 2School of Civil Engineering,Chongqing University of Science and Technology,Chongqing 401331,China
  • 3School of City and Architecture Engineering,Zaozhuang University,Zaozhuang 277160,China
  • 4China Construction Fifth Engineering Division Crop,Ltd.,Changsha 410004,China
  • show less
    Figures & Tables(8)
    Schematic diagram of the FBG-based vector displacement sensing device
    Schematic diagram of sensing device deformation structure
    Calibration tests of six groups of FBG sensing devices CSE
    Calibration results of six groups of FBG sensing devices CSE
    Indoor model test of an accumulation slope and sensors layout
    Comparison of the monitored displacements on the surface of accumulation slope model
    Relative errors of the monitored displacements on the surface of accumulation slope model
    • Table 1. Comparison between FBG sensing device and PIV for measuring displacement azimuth angle

      View table
      View in Article

      Table 1. Comparison between FBG sensing device and PIV for measuring displacement azimuth angle

      Loading

      times

      Measurement point 1Measurement point 2Measurement point 3
      PIVFBGErrorPIVFBGErrorPIVFBGError
      147.11°46.29°-1.74%69.94°70.00°0.09%59.59°58.62°-1.63%
      242.39°45.08°6.35%49.23°53.86°9.39%72.16°69.27°-4.00%
      339.63°43.71°10.31%70.57°70.00°-0.81%71.30°70.00°-1.82%
      446.34°43.84°-5.40%72.72°70.00°-3.74%68.38°66.78°-2.33%
      544.88°45.43°1.22%66.80°68.86°3.07%67.65°68.13°0.71%
      642.32°39.61°-6.41%70.33°70.00°-0.47%69.24°68.07°-1.69%
      739.28°42.00°6.93%69.98°69.31°-0.96%69.85°70.82°1.38%
      843.18°40.47°-6.28%68.34°70.37°2.98%72.06°70.23°-2.54%
      945.11°41.54°-7.92%68.56°69.39°1.21%69.04°68.72°-0.46%
    Tools

    Get Citation

    Copy Citation Text

    Yong ZHENG, Jie YU, Hongkai CHEN, Xing YI. A Vector Displacement Measurement Sensing Device Based on Fiber Bragg Grating and Its Experimental Study[J]. Acta Photonica Sinica, 2024, 53(2): 0206005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Fiber Optics and Optical Communications

    Received: Jul. 17, 2023

    Accepted: Sep. 11, 2023

    Published Online: Mar. 28, 2024

    The Author Email: YU Jie (cquyujie@sina.com)

    DOI:10.3788/gzxb20245302.0206005

    Topics