Infrared and Laser Engineering, Volume. 50, Issue S2, 20200393(2021)

Current harmonics suppression of the large aperture telescope based on segmented arc PMSM

Xiaoli Song1,2, Hemin Sun4, Daxing Wang1,2, and Chi Zhang1,2,3
Author Affiliations
  • 1National Astronomical Observatories / Nanjing Institute of Astronomical Optics & Technology, Chinese Academy of Sciences, Nanjing 210042, China
  • 2CAS Key Laboratory of Astronomical Optics & Technology, Nanjing Institute of Astronomical Optics & Technology, Nanjing 210042, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • 4Nanjing University of Information Science & Technology, Nanjing 210044, China
  • show less
    Figures & Tables(11)
    Structure distribution of segmented arc motor for large aperture telescope. (a) Stator winding; (b) Mechanical structure
    Dynamic structure of motor current loop
    PR controller Bode diagram on ideal condition
    PR controller Bode diagram when varying变化PR控制器伯德图
    PR controller Bode diagram when varying变化PR控制器伯德图
    Quasi-PR controller design of the current loop
    Drive and control platform of segmented arc PMSM. (a) Physical drawing of arc PMSM; (b) Drive and control circuit board
    Simulations comparison of current wave and harmonic analysis between PI and PR controller. (a) Current wave of one period (PI); (b) Current wave of one period (QPR); (c) Harmonics percentage of magnitude of current of simulation (PI); (d) Harmonics percentage of magnitude of current of simulation (QPR)
    Experiments comparison of current wave and harmonic analysis between PI and PR controller. (a) Current wave of PI; (b) Current wave of QPR; (c) Magnitude percentage of current harmonics of experiment (PI); (d) Magnitude percentage of current harmonics of experiment (QPR)
    • Table 1. Current harmonic percentage of simulation comparison between PI and QPR

      View table
      View in Article

      Table 1. Current harmonic percentage of simulation comparison between PI and QPR

      Harmonics NFundamental harmonic of PIFundamental harmonic of QPRWeaken of all harmonics
      50.6638%0.1231%81.4%
      70.8652%0.1908%77.9%
      110.3389%0.1005%70.4%
      130.3164%0.0298%90.5%
    • Table 2. Current harmonic percentage of experiment comparison between PI and QPR

      View table
      View in Article

      Table 2. Current harmonic percentage of experiment comparison between PI and QPR

      Harmonics NFundamental harmonic of PIFundamental harmonic of QPRWeaken of all harmonics
      51.659%0.6096%63.3%
      70.8924%0.5855%34.4 %
      110.5495%0.2692%51.0%
      130.4372%0.1785%59.2%
    Tools

    Get Citation

    Copy Citation Text

    Xiaoli Song, Hemin Sun, Daxing Wang, Chi Zhang. Current harmonics suppression of the large aperture telescope based on segmented arc PMSM[J]. Infrared and Laser Engineering, 2021, 50(S2): 20200393

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Sep. 3, 2020

    Accepted: --

    Published Online: Dec. 3, 2021

    The Author Email:

    DOI:10.3788/IRLA20200393

    Topics