Infrared and Laser Engineering, Volume. 50, Issue 10, 20200454(2021)

Application of split-image mirror in defocus detection of laser rangefinder

Mingze Qin... Yuan Hu, Wenjun He, Yang Zheng, Yuhao Chu, Xiyao Yuan and Wenxuan Li |Show fewer author(s)
Author Affiliations
  • School of Opto-electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
  • show less
    References(17)

    [1] Xiaokun Gu, Yongliang Li, Weiwei Hu, et al. Research progress of dector unit in laser ranging system. Journal of Quantum Optics, 25, 106-114(2019).

    [2] Hexiong Liu, Bing Zhou, Yuchen Gao. Research of noise characteristics and influence factors of APD detection systems. Laser Technology, 042, 862-867(2018).

    [3] Bo Liu, Nianjiang Chen, Zhongping Zhang, et al. Micro pulse laser ranging technology for human satellite. Infrared and Laser Engineering, 37, 234-237(2008).

    [4] [4] Xu Xiang. The study of multifunctional laser ranging finder system[D]. Changsha: National University of Defense Technology, 2006. (in Chinese)

    [5] [5] Hu Yifei. Research of confocal laser measurement method f dimensional measurement of wkpiece cavity[D]. Xi''an: Xi''an University of Science Technology, 2019. (in Chinese)

    [6] Qijun Luo, Baozhen Ge. An automatic focusing method of a telescope objective lens based on the defocusing estimation of a circular edge response. Chinese Optics, 13, 760-769(2020).

    [7] Tingjia Jiang, Man Jiang, Bin Ruan, et al. Effect of the center deviation of focusing spot on the measurement precision in the astigmatic defocus detecting system. Optical Technology, 39, 483-487(2013).

    [8] Xianpeng Hao, Jianyue Ren, Zhenshu Zou. Design of focus error detection system based on critical angle method. Optics and Precision Engineering, 17, 537-541(2009).

    [9] Yunhai Zhang, Gaina Zhao, Zhonghua Zhang, et al. Accurate focusing of non-mydriatic fundus camera. Optics and Precision Engineering, 17, 1014-1019(2009).

    [10] Xingyun Liu, Dejin Hu. Simulative experimental instrument based on central split-image focusing. Physics Experimentation, 29-31(2003).

    [11] Hui Zhong. Focal plane alignment for remote sensing camera with dual focal plane of large field of view interval. Infrared and Laser Engineering, 50, 20200172(2021).

    [12] [12] Yu Daoyin, Tan Hengying. Engineering Optics[M]. Beijing: China Machine Press, 2011. (in Chinese)

    [13] [13] Ma Hong, Wang Jinbo. They of Instrument Accuracy[M]. Beijing: Beijing University Press, 2014. (in Chinese)

    [14] Yuping Zhao, Chuanqian Peng, Jie Wang, et al. Analysis of error source for large aperture thin beam auto-collimating measurement system. Semiconductor Optoelectronics, 39, 414-419(2018).

    [15] Zhiji Cheng, Qiangxian Huang, Qiancheng Ying, et al. Analysis and correction of defocus error of auto-collimation measurement system. China Measurment, 46, 7-12(2020).

    [16] [16] Chengdu Guangming Optoelectronics Co., Ltd. Chengdu Guangming Optical Glass Library Data[Z]. Chengdu: Chengdu Guangming Optoelectronics Co., Ltd., 2019.

    [17] Bo Lv, Guohua Han. Application of dual wedges in optical axis alignment for laser rangefinders. Laser Technology, 36, 151-153,159(2012).

    Tools

    Get Citation

    Copy Citation Text

    Mingze Qin, Yuan Hu, Wenjun He, Yang Zheng, Yuhao Chu, Xiyao Yuan, Wenxuan Li. Application of split-image mirror in defocus detection of laser rangefinder[J]. Infrared and Laser Engineering, 2021, 50(10): 20200454

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Photoelectric measurement

    Received: Dec. 20, 2020

    Accepted: --

    Published Online: Dec. 7, 2021

    The Author Email:

    DOI:10.3788/IRLA20200454

    Topics