Acta Optica Sinica, Volume. 42, Issue 23, 2328002(2022)

Temperature Sensor Cascading Reflective Fabry-Perot Cavity with Microring Resonator

Jiayi Xie1, Guoshuai Su1, Mingyu Li1、*, and JianJun He2
Author Affiliations
  • 1Department of Optical Engineering, School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun 130022, Jilin , China
  • 2State Key Laboratory of Modern Optical Instrumentation, Zhejiang University, Hangzhou 310027, Zhejiang , China
  • show less
    Figures & Tables(10)
    Schematic diagram of intensity interrogation device based on temperature sensor
    Principle of intensity interrogation method based on temperature sensor. (a) Input spectrum of BLS and transmission spectrum at ΔT=0; (b) output spectrum of temperature sensor at ΔT=0; (c) input spectrum of BLS and transmission spectrum at ΔT>0; (d) output spectrum of temperature sensor at ΔT>0
    Relationship between output power ratio of intensity interrogation method and temperature change
    Output power ratio varying with temperature under different differences between FP etalon free spectral range and MRR free spectral range
    Experimental setup for temperature sensor and optical microscope diagram of MRR. (a) Experimental setup for temperature sensor; (b) main part of experimental setup for temperature sensor; (c) optical microscope diagram of MRR
    Transmission spectrum of temperature sensor and spectrum of combined light source
    Data points of intensity interrogation and fitting curve
    P2/P1 value varying with time at temperature of 26 ℃
    • Table 1. Values and variances of P2/P1 detected in three experiments

      View table

      Table 1. Values and variances of P2/P1 detected in three experiments

      Temperature /℃P2/P1 in 1st experiment /dBP2/P1 in 2nd experiment /dBP2/P1 in 3rd experiment /dBVariance /(10-5 dB)
      20.0-26.368-26.372-26.3631.4
      20.5-26.785-26.779-26.7675.6
      21.0-27.359-27.351-27.3727.5
      21.5-26.824-26.832-26.85719.6
      22.0-26.241-26.250-26.2638.2
      22.5-25.051-25.056-25.0749.7
      23.0-24.320-24.306-24.3315.0
      23.5-23.295-23.289-23.25313.8
      24.0-22.284-22.287-24.2674.2
      24.5-21.847-21.860-21.8583.3
      25.0-21.353-21.358-21.3472.0
      25.5-21.770-21.761-21.7806.0
      26.0-22.310-22.290-22.3067.5
    • Table 2. P2/P1 values detected in five experiments at temperature of 20 ℃

      View table

      Table 2. P2/P1 values detected in five experiments at temperature of 20 ℃

      Experiment No.12345
      P2P1 /dB-26.368-26.372-26.363-26.359-26.375
    Tools

    Get Citation

    Copy Citation Text

    Jiayi Xie, Guoshuai Su, Mingyu Li, JianJun He. Temperature Sensor Cascading Reflective Fabry-Perot Cavity with Microring Resonator[J]. Acta Optica Sinica, 2022, 42(23): 2328002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: May. 10, 2022

    Accepted: Jun. 16, 2022

    Published Online: Dec. 14, 2022

    The Author Email: Li Mingyu (limingyu@cust.edu.cn)

    DOI:10.3788/AOS202242.2328002

    Topics