NUCLEAR TECHNIQUES, Volume. 47, Issue 2, 020401(2024)

Development of the high-resolution neutron scintillator detector for the very small-angle neutron scattering spectrometer

Huiyin LIU1,2,3, Jie YANG1、*, Chang HUANG2,3, Bin TANG2,3、**, Shihui ZHOU2,3, Xiaojie CAI2,3, Xiuku WANG2,3, Lixin ZENG2,3, Xiuping YUE2,3, Shaojia CHEN2,3, Hong XU2,3, Dawei GUO2,3, Xu CHEN2,3, and Zhijia SUN2,3
Author Affiliations
  • 1Zhengzhou University, Zhengzhou 450001, China
  • 2Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
  • 3Spallation Neutron Source Science Center, Dongguan 523803, China
  • show less

    Background

    The very small-angle neutron scattering (VSANS) spectrometer is currently being constructed at the China spallation neutron source (CSNS). The neutron detector plays a key role in meeting the detection requirements of the spectrometer.

    Purpose

    This study aims to achieve accurate measurement of neutron diffraction in the small angle scattering mode which requires the position resolution of the neutron detector to be ≤2 mm, and the detection efficiency to be ≥60%@0.4 nm.

    Methods

    A large-area position-sensitive neutron scintillator detector mainly composed of 6LiF/ZnS(Ag) scintillation screen, wavelength shift fiber (WLSF), and a silicon photomultiplier (SiPM) was designed and developed to achieve high efficiency and high-resolution real-time detection of thermal neutrons. The optical transmission performance of the 0.5-mm-diameter wavelength shift fiber was investigated in detail. The gain and the thermal noise characteristics of various SiPMs were examined. Finally, a 300 mm×300 mm engineering prototype of the detector was developed and tested by experiments. The detection efficiency was calculated with comparison of the incident neutron counts of the stander 3He tube whilst the detector's position resolution was tested using a boron-doped aluminum plate with a narrow slit bearing the label 'CSNS'.

    Results

    The neutron beam test results show that the position resolution of the detector is 1.2 mm×1.2 mm and that the neutron detection efficiency is (61.8±0.2)%@0.4 nm.

    Conclusions

    The high-resolution neutron scintillator detector developed in this study satisfies the engineering design target, and meets the neutron scintillator detector meets the neutron diffraction measurement needs for the VSANS spectrometer of the CSNS.

    Tools

    Get Citation

    Copy Citation Text

    Huiyin LIU, Jie YANG, Chang HUANG, Bin TANG, Shihui ZHOU, Xiaojie CAI, Xiuku WANG, Lixin ZENG, Xiuping YUE, Shaojia CHEN, Hong XU, Dawei GUO, Xu CHEN, Zhijia SUN. Development of the high-resolution neutron scintillator detector for the very small-angle neutron scattering spectrometer[J]. NUCLEAR TECHNIQUES, 2024, 47(2): 020401

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Research Articles

    Received: Jun. 26, 2023

    Accepted: --

    Published Online: Apr. 24, 2024

    The Author Email: YANG Jie (杨洁), TANG Bin (唐彬)

    DOI:10.11889/j.0253-3219.2024.hjs.47.020401

    Topics