Infrared and Laser Engineering, Volume. 44, Issue 12, 3701(2015)

Thermal cycle characteristic of InSb focal plane array detector

Wang Yang1、*, Lu Xing2, Meng Chao1,3, Liu Junming1,3, Kuang Yongbian1,3, Meng Qingduan4, Zhu Xubo1,3, and Si Junjie1,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    References(17)

    [5] [5] Wu Hanping. Research into testing scheme of reliability qualification of complex optoeletronic systems[J]. Optics and Precision Engineering, 1997, 5(5): 112-120. (in Chinese)

    [7] [7] Xavier Breniere, Philippe Tribolet. IR detectors design and approach for tactical applications with high reliability without maintenance[C]//SPIE, 2008, 6940: 69400H.

    [8] [8] Xavier Breniere, Alain Manissadjian, Michel Vuillermet, et al. Reliability optimization for IR detectors with compact cryo-cooler [C]//SPIE, 2005, 5783: 607591.

    [9] [9] Xavier Breniere, Philippe Tribolet. IR detectors life cycle cost and reliability optimization for tactical application [C]//SPIE, 2006, 6395: 63950D.

    [10] [10] Marianne Molina,Xavier Breniere, Philippe Tribolet. IR detector Dewar and assemblies for stringent environmental conditions [C]//SPIE, 2007, 6542: 65422N.

    [11] [11] Davis M, Devitt J. Advanced FPA technology development at CMC Electronics[C]//SPIE, 2004, 5563.

    [12] [12] Zhu Yingfeng,Han Fuzhong, Li Dongsheng, et al. MW 320×256 IRFPA detector under rapid cooling down[J]. Infrared and Laser Engineering, 2014, 43(4): 1032-1036. (in Chinese)

    [13] [13] Meng Chao, Peng Jing, Ma Wei. Study on reliability enhancement testing for InSb focal plane array detector[C]//SPIE, 2012, 8193.

    [14] [14] Ren Ren, Wu Ligang, Wang Xiaokun, et al. Study on the thermal cycle characteristic of HgCdTe detector[J]. Laser & Infrared, 2007, 37: 941-943. (in Chinese)

    [15] [15] The National Standard Office. GB 2689.1-81.The General Principle of Constant Stress Life Test and Accel-erated Life Test[S]. Beijing: Standards Press of China,1981.(in Chinese)

    [16] [16] Wang Wujie, Liu Yongqiang, Zheng Bin. Research on Dewar heat leakage detecting technologies using infrared detectors[J]. Journal of Test and Measurem Engtechnology, 2008, 22(3): 222-224. (in Chinese)

    CLP Journals

    [1] Xiaohan Tian, Jiangfeng Zhang, Xiaoling Zhang, Qingduan Meng. Effects of isolation trough on cleavage of InSb chip in InSb detector[J]. Infrared and Laser Engineering, 2022, 51(5): 20210599

    Tools

    Get Citation

    Copy Citation Text

    Wang Yang, Lu Xing, Meng Chao, Liu Junming, Kuang Yongbian, Meng Qingduan, Zhu Xubo, Si Junjie. Thermal cycle characteristic of InSb focal plane array detector[J]. Infrared and Laser Engineering, 2015, 44(12): 3701

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: 光电器件与材料

    Received: Apr. 17, 2015

    Accepted: May. 18, 2015

    Published Online: Jan. 26, 2016

    The Author Email: Yang Wang (446364485@qq.com)

    DOI:

    Topics