Acta Optica Sinica, Volume. 37, Issue 8, 0801003(2017)

Automated Radiation Calibration Method Based on DunhuangRadiometric Calibration Site

Jiayan Lü1, Mingyuan He1, Lin Chen2,3、*, Xiuqing Hu2,3, and Xin Li4
Author Affiliations
  • 1 College of Meteorology and Oceanography, PLA University of Science and Technology,Nanjing, Jiangsu 211101, China
  • 2 National Satellite Meteorological Center, China Meteorological Administration, Beijing 100081, China
  • 3 Key Laboratory of Radiometric Calibration and Validation for Environmental Satellite,China Meteorological Administration, Beijing 100081, China
  • 4 Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • show less
    References(18)

    [1] Xu Weiwei, Zhang Liming, Yang Benyong et al. On-orbit radiometric calibration based on gray-scale tarps[J]. Acta Optica Sinica, 32, 0212007(2012).

    [6] Li Yuan, Rong Zhiguo, Zheng Zhaojun et al. Post launch site calibration of visible and near-infrared channels of FY-3A visible and infrared radiometers[J]. Optics and Precision Engineering, 17, 2966-2974(2009).

    [7] Gong Hui, Tian Guoliang, Yu Tao et al. Vicarious radiometric calibration and validation of CBERS02B CCD data[J]. Journal of Remote Sensing, 14, 1-12(2010).

    [8] Gao Hailiang, Gu Xingfa, Yu Tao et al. HJ-1A HIS on-orbit radiometric calibration and validation research[J]. Science China Technological Sciences, 40, 1312-1321(2010).

    [9] Han Qijin, Ma Lingling, Liu Li et al. On-orbit calibration and evaluation of GF-2 satellite based on wide dynamic target[J]. Acta Optica Sinica, 35, 0728003(2015).

    [10] Zhang Xuewen, Fu Qiaoyan, Han Qijin et al. The field radiometric calibration and validation of ZY-3 multispectral sensor[J]. Spectroscopy and Spectral Analysis, 34, 2476-2480(2014).

    [11] Chen Lin, Xu Na, Hu Xiuqing et al. Study on orbit radiometric calibration for FY-2 visible band based on deep convective cloud[J]. Spectroscopy and Spectral Analysis, 36, 2639-2645(2016).

    [14] Qiu Ganggang, Li Xin, Wei Wei et al. Experiment and analysis of on-orbit radiometric calibration for remote sensors based on in-site automated observation technology[J]. Acta Optica Sinica, 36, 0701001(2016).

    [15] Gao Hailiang, Gu Xingfa, Yu Tao et al[J]. The research overview on visible and near-infrared channels radiometric calibration of space-borne optical remote sensors Remote Sensing Information, 2010, 117-128.

    [16] Sun Ling, Guo Maohua, Xu Na et al. On-orbit response variation analysis of FY-3 MERSI reflective solar bands based on Dunhuang site calibration[J]. Spectroscopy and Spectral Analysis, 32, 1869-1877(2012).

    [18] Xu Na, Hu Xiuqing, Chen Lin et al. Cross-calibration of FY-2E/VISSR infrared window and water vapor channels with TERRA/MODIS[J]. Journal of Infrared Millimeter Waves, 31, 319-324(2012).

    Tools

    Get Citation

    Copy Citation Text

    Jiayan Lü, Mingyuan He, Lin Chen, Xiuqing Hu, Xin Li. Automated Radiation Calibration Method Based on DunhuangRadiometric Calibration Site[J]. Acta Optica Sinica, 2017, 37(8): 0801003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Atmospheric Optics and Oceanic Optics

    Received: Mar. 8, 2017

    Accepted: --

    Published Online: Sep. 7, 2018

    The Author Email: Chen Lin (chenlin@cma.gov.cn)

    DOI:10.3788/AOS201737.0801003

    Topics