Acta Optica Sinica, Volume. 32, Issue 4, 409003(2012)

Depth Selectivity of Aperiodic Volume Grating in Holographic Imaging System

Lin Lin1,2、*, Wan Yuhong1,2, Chen Hao1,2, Wu Jiangtao1,2, Jiang Zhuqing1,2, and Tao Shiquan1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(10)

    [1] [1] Zheng Guangwei, Tan Jichun, Shen Benjian et al.. Research on harmonic wave separation and beam sampling characteristics of superposed volume Bragg gratings[J]. Acta Optica Sinica, 2011, 31(3): 0305001

    [4] [4] Arnab Sinha, Wenyang Sun, Tina Shih et al.. Volume holographic imaging in transmission geometry[J]. Appl. Opt., 2004, 43(7): 1533~1551

    [5] [5] Arnab Sinha, George Barbaststhis. Volume holographic for surface metrology at long working distances[J]. Opt. Express, 2003, 11(24): 3202~3209

    [6] [6] Yuan Luo, Paul J. Gelsinger-Austin, Jonathan M. Watson et al.. Laser-induced fluorescence imaging of subsurface tissue structures with a volume holographic spatial-spectral imaging system[J]. Opt. Lett., 2008, 33(18): 2098~2100

    [7] [7] Yang Jing. Imaging Characteristics of a Volume Holographic Lens[D]. Beijing: Beijing University of Technology, 2010. 25~30

    [8] [8] Yuan Luo, Jose Castro, Jennifer K. Barton et al.. Simulations and experiments of aperiodic and multiplexed gratings in volume holographic imaging systems[J]. Opt. Express, 2010, 18(18): 19273~19285

    [9] [9] Tao Shiquan, Jiang Zhuqing, Wang Dayong et al.. Holographic Optics Storage[M]. Beijing: Publishing House of Beijing University of Technology, 1998. 58~75

    [10] [10] R. R. A. Syms, L. Solymar. Localized one-dimensional theory for volume holograms[J]. Opt. & Quantum Electron., 1981, 13(5): 415~419

    CLP Journals

    [1] He Tianbo, Bayanheshig, Zhang Shanwen, Li Wenhao, Tang Yuguo. Calculation Method of Diffraction Efficiency and Characteristics of Non-Uuniform Mixed Modulation Gratings[J]. Chinese Journal of Lasers, 2014, 41(8): 809001

    Tools

    Get Citation

    Copy Citation Text

    Lin Lin, Wan Yuhong, Chen Hao, Wu Jiangtao, Jiang Zhuqing, Tao Shiquan. Depth Selectivity of Aperiodic Volume Grating in Holographic Imaging System[J]. Acta Optica Sinica, 2012, 32(4): 409003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Holography

    Received: Oct. 19, 2011

    Accepted: --

    Published Online: Feb. 24, 2012

    The Author Email: Lin Lin (linlin_86@emials.bjut.edu.)

    DOI:10.3788/aos201232.0409003

    Topics