Laser & Optoelectronics Progress, Volume. 60, Issue 24, 2430001(2023)

Influencing Factors of Mid-Infrared Spectrum Blood Glucose Detection

Yansong Yue1,2,3, Zhushanying Zhang1,2,3、*, Sicong Zhu1,2,3, Huimin Cao1,2,3, Dongyun Zheng1,2,3, and Qinlan Xie1,2,3
Author Affiliations
  • 1School of Biomedical Engineering, South-Central Minzu University, Wuhan 430074, Hubei, China
  • 2Key Laboratory of Cognitive Science, State Ethnic Affairs Commission, South-Central Minzu University, Wuhan 430074, Hubei, China
  • 3Hubei Key Laboratory of Medical Information Analysis and Tumor Diagnosis&Treatment, Wuhan 430074, Hubei, China
  • show less
    Figures & Tables(9)
    Original measurement spectra. (a) Model 1; (b) model 2; (c) model 3; (d) model 4
    Flow chart of mid-infrared spectroscopy glucose detection modeling and analysis
    SG smooth spectra. (a) Model 1; (b) model 2; (c) model 3; (d) model 4
    Clarke Error Grid based on four subset models. (a) Model 1; (b) model 2; (c) model 3; (d) model 4
    Predicted values versus true values. (a) Model 1; (b) model 2; (c) model 3; (d) model 4
    • Table 1. Mass concentration range of substances

      View table

      Table 1. Mass concentration range of substances

      IndexGlucoseAlbuminUreaCholesterol
      Mass concentration0‒4800‒60000‒900‒200
      Mass concentration gradient2020003050
    • Table 2. Composition of background solution samples

      View table

      Table 2. Composition of background solution samples

      Sample numberComposition
      14.00 mL 10% intralipid solutions
      20.25 mL ethanol and 3.75 mL 10% intralipid solutions
      30.50 mL ethanol and 3.50 mL 10% intralipid solutions
      40.75 mL ethanol and 3.25 mL 10% intralipid solutions
      51.00 mL ethanol and 3.00 mL 10% intralipid solutions
    • Table 3. Model performance metrics based on different subsets

      View table

      Table 3. Model performance metrics based on different subsets

      ModelRMSECVfRpRMSEP
      139.7370100.978540.0187
      217.7817120.9042175.7292
      325.1170120.9616103.6627
      453.6867140.974238.6716
    • Table 4. Percentage of points for different models located in corresponding areas of the Clarke Error Grid

      View table

      Table 4. Percentage of points for different models located in corresponding areas of the Clarke Error Grid

      ModelABCDE
      185.7%14.3%
      240.0%40.0%20.0%
      342.9%42.9%14.3%
      4100.0%
    Tools

    Get Citation

    Copy Citation Text

    Yansong Yue, Zhushanying Zhang, Sicong Zhu, Huimin Cao, Dongyun Zheng, Qinlan Xie. Influencing Factors of Mid-Infrared Spectrum Blood Glucose Detection[J]. Laser & Optoelectronics Progress, 2023, 60(24): 2430001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Spectroscopy

    Received: Apr. 6, 2023

    Accepted: May. 15, 2023

    Published Online: Nov. 27, 2023

    The Author Email: Zhang Zhushanying (syzhu@mail.scuec.edu.cn)

    DOI:10.3788/LOP231035

    Topics