High Power Laser and Particle Beams, Volume. 33, Issue 12, 123025(2021)

Signal compensation of coaxial cable based on Wiener filtering method

Guangsen Chen1...2, Feng Qin2,3,*, and Yuan Gao23,* |Show fewer author(s)
Author Affiliations
  • 1Graduate School of China Academy of Engineering Physics, Mianyang 621999, China
  • 2Institute of Applied Electronics, CAEP, Mianyang 621999, China
  • 3Key Laboratory of Science and Technology on Complex Electromagnetic Environment, China Academy of Engineering Physics, Mianyang 621999, China
  • show less
    Figures & Tables(10)
    Schematic diagram of Wiener filtering method
    Solution flow of Wiener filtering method
    Schematic illustrating the experimental setup for signal compensation in coaxial cable
    S21 parameter of 10 mcoaxial cable
    Compensation of a Gaussian modulated pulse signal by using Wiener filtering method
    Compensation of other two types of signals using Wiener filtering method
    Comparisons between the input signals and compensated signals using Wiener filtering method as well as attenuation compensation method for different types of signals
    • Table 1. Relative error (RE) between the input signal (IS) and output signal (OS) as well as compensated signals (CS) using Wiener filtering method

      View table
      View in Article

      Table 1. Relative error (RE) between the input signal (IS) and output signal (OS) as well as compensated signals (CS) using Wiener filtering method

      RE between IS and OS/%RE between IS and CS/%
      double exponential pulse signal14.003.30
      Gaussian modulated pulse signal21.624.85
      modulated square wave signal33.905.01
    • Table 2. Relative error (RE) between the input signals and compensated signals using Wiener filtering method (WF) and attenuation compensation method (AC)

      View table
      View in Article

      Table 2. Relative error (RE) between the input signals and compensated signals using Wiener filtering method (WF) and attenuation compensation method (AC)

      RE using AC/%RE using WF/%
      double exponential pulse signal8.483.30
      Gaussian modulated pulse signal9.274.85
      modulated square wave signal10.645.01
    • Table 3. Comparisons of the efficiency for different types of signals using Wiener filtering method and attenuation compensation method

      View table
      View in Article

      Table 3. Comparisons of the efficiency for different types of signals using Wiener filtering method and attenuation compensation method

      time of WF/stime of AC/s
      double exponential pulse signal0.840.77
      Gaussian modulated pulse signal0.890.78
      modulated square wave signal0.900.83
    Tools

    Get Citation

    Copy Citation Text

    Guangsen Chen, Feng Qin, Yuan Gao. Signal compensation of coaxial cable based on Wiener filtering method[J]. High Power Laser and Particle Beams, 2021, 33(12): 123025