Optical Communication Technology, Volume. 48, Issue 1, 1(2024)

Review on the development of fiber laser sensor structures

JIA Zhen'an1...2,3,4, ZHANG Heng1,2,3,4, GAO Hong1,2,3,4, YU Dakuan1,2,3,4, and LIU Qinpeng1,2,34 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • 4[in Chinese]
  • show less
    References(24)

    [1] [1] QIN Q, ZHU W, XI B, et al. Magnetic flux leakage detection based on a sensitivity-enhanced fiber Bragg grating magnetic field sensor[J]. Applied Optics, 2023, 62(16): E62-E69.

    [2] [2] KHAN R Y M, ULLAH R, FAISAL M. Design and development of type-1 FBG based high temperature sensor along with sensing probes[J]. Physica Scripta, 2023, 98(4): 045515-1-045515-11.

    [3] [3] YU H, WANG X, GAO W, et al. Dual-parameter measurements of curvature and strain using cladding-etched two-mode fiber Bragg grating[J]. Optical Fiber Technology, 2023, 78: 103319-1-103319-7.

    [7] [7] HUANG F Q, CHEN T S, XU J H, et al. Fiber laser based on a fiber Bragg grating and its application in high-temperature sensing[J]. Optics Communications, 2019, 452: 233-237.

    [8] [8] JAHARUDIN N A N, CHOLAN N A, OMAR M A, et al. Fiber Bragg grating based linear cavity fibre laser temperature sensor with enhanced optical signal-to-noise ratio[J]. Laser Physics, 2020, 30(1): 015101-1-015101-6.

    [12] [12] YE C, CHEN Z, TONG Z R. All fiber sensor based on Mach-Zehnder interferometer for simultaneous measurement of temperature and refractive index[J]. Optoelectronics Letters, 2015, 11(6): 438-443.

    [13] [13] CHAO L, TIGANG N, JING L, et al. Fiber-optic laser sensor based on all-fiber multipath Mach-Zehnder interferometer[J]. IEEE Photonics Technology Letters, 2016, 28(18): 1908-1911.

    [14] [14] NIU P P, JIANG J, LIU K, et al. Low detection limit refractive index sensor based on open microcavity Mach-Zehnder interferometer and fiber ring laser[C]//SPIE. Advanced Sensor Systems and Applications X, Bell-ingham: SPIE, 2020, 11554: 42-47.

    [15] [15] CONTRERAS-TERAN M A, JAUREGUI-VAZQUEZ D, GALLEGOS-ARELLANO E, et al. High-resolution strain fiber laser-sensor based on core-offset mach-zehnder interferometer[J]. Measurement Science and Technology, 2023, 34(5): 055202-1-055202-9.

    [17] [17] WANG D, WU Y, ZHU L, et al. High sensitivity fiber optic acceleration sensor based on Fabry-Perot interferometer[J]. Optical Fiber Technology, 2022, 72: 102989-1-102989-8.

    [19] [19] WEI H M, KRISHNASWAMY S. Adaptive fiber-ring lasers based on an optical fiber Fabry-Perot cavity for high-frequency dynamic strain sensing[J]. Applied Optics, 2020, 59(2): 530-535.

    [22] [22] LIU S, LU G, LV D, et al. Sensitivity enhanced temperature sensor with cascaded Sagnac loops based on harmonic vernier effect[J]. Optical Fiber Technology, 2021, 66: 102654-1-102654-6.

    [23] [23] LU H L, YUE Y L, DU J, et al. Temperature and liquid refractive index sensor using P-D fiber structure-based Sagnac loop[J]. Optics Express, 2018, 26(15): 18920-18927.

    [24] [24] OMAR M A, CHOLAN N A, ABDULRAHMAN A M, et al. Fiber laser temperature sensor based on Sagnac interferometer[J]. Journal of Phy-sics, Conference Series, 2019, 1371(1): 012016-1-012016-6.

    [25] [25] YANG F, WU Y J, SHI J, et al. Curvature sensor based on fiber ring laser with Sagnac loop[J]. Optical Fiber Technology, 2020, 60: 102341-1-102341-5.

    [26] [26] MENG D J, MIAO C Y, LI X G, et al. A vibration sensor based on Sagnac interferometer and fiber ring laser for fault diagnosis of bearing[J]. Optical Fiber Technology, 2021, 64: 102554-1-102554-7.

    [30] [30] LIANG X, LIU Z, WEI H, et al. Detection of liquid level with an MI-based fiber laser sensor using few-mode EMCF[J]. IEEE Photonics Technology Letters, 2015, 27(8): 805-808.

    [31] [31] LIN W H, SHAO L Y, LIU Y B, et al. Temperature sensor based on fiber ring laser with cascaded fiber optic Sagnac interferometers[J]. IEEE Photonics Journal, 2021, 13(2): 1-12.

    [32] [32] SHI J, WANG Y, XU D, et al. Remote gas pressure sensor based on fiber ring laser embedded with Fabry-Perot interferometer and sagnac loop[J]. IEEE Photonics Journal, 2016, 8(5): 1-8.

    [33] [33] WANG X, WANG L, WANG J, et al. High sensitivity interrogation system of fiber Bragg grating sensor with composite cavity fiber laser[J]. Optics & Laser Technology, 2021, 142(1): 107228-1-107228-6.

    [34] [34] YANG X C, LIU Y H, SUN X H, et al. Strain- and temperature-sensing characteristics of fiber ring laser sensor with cascaded Fabry-Perot interferometer and FBG[J]. IEEE Transactions on Instrumentation and Measurement, 2021, 70: 1-7.

    [35] [35] WANG X, CHEN T W, MENG D L, et al. A simple FBG Fabry-Perot sensor system with high sensitivity based on fiber laser beat frequency and vernier effect[J]. IEEE Sensors Journal, 2020, 21(1): 71-75.

    Tools

    Get Citation

    Copy Citation Text

    JIA Zhen'an, ZHANG Heng, GAO Hong, YU Dakuan, LIU Qinpeng. Review on the development of fiber laser sensor structures[J]. Optical Communication Technology, 2024, 48(1): 1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Apr. 28, 2023

    Accepted: --

    Published Online: Jun. 20, 2024

    The Author Email:

    DOI:10.13921/j.cnki.issn1002-5561.2024.01.001

    Topics