Laser & Optoelectronics Progress, Volume. 58, Issue 19, 1926001(2021)

Analysis of Phase Error of Retarders in Spectrally Encoded Mueller Matrix Measurement

Shuqiang Huang1, Xiumei Jiang1, and Yuanhua Feng2,3、*
Author Affiliations
  • 1Department of Optoelectronic Engineering, College of Science and Engineering, Jinan University, Guangzhou , Guangdong 510632, China
  • 2Department of Electronic Engineering, College of Information Science and Technology, Jinan University, Guangzhou , Guangdong 510632, China
  • 3State Key Laboratory of Integrated Optoelectronics, Beijing 100083, China
  • show less
    Figures & Tables(7)
    Schematic of experimental setup of spectrally encoded Mueller matrix measurement system
    Measurement spectrum with 0° polarizer as sample
    Influence of phase ϕw on the Mueller matrix for different samples
    The value of each element of the Muller matrix with the compensation of polarizer from 0° to 90°
    • Table 1. Influence of Δϕ2,Δϕ3,and Δϕ4 on the Mueller matrix for different samples and the compensation effect

      View table

      Table 1. Influence of Δϕ2,Δϕ3,and Δϕ4 on the Mueller matrix for different samples and the compensation effect

      ϕ2 /radϕ3 /radϕ4 /radERMS of vacuumERMS of polarizer(θ=45°ERMS of quarter waveplate(θ=45°
      Without compensationWith compensationWithout compensationWith compensationWithout compensationWith compensation
      0.01000.00300.00130.00400.00240.00510.0023
      0.1000.03300.00130.03510.00240.03660.0023
      00.0100.00300.00130.00400.00240.00450.0023
      00.100.03300.00130.03510.00240.03580.0023
      000.010.00300.00130.00400.00240.00510.0023
      000.10.03300.00130.03510.00240.04360.0023
      0.010.010.010.01060.00130.00790.00240.00930.0023
      0.10.10.10.10830.00130.07900.00240.08360.0023
      0.10.1-0.10.04320.00130.03550.00240.04440.0023
    • Table 2. Comparison with and without compensation of different samples using polarizer method

      View table

      Table 2. Comparison with and without compensation of different samples using polarizer method

      SampleTheoretical Muellermatrix

      Experimental Mueller

      matrix

      Mueller matrix element error
      Without compensationWith compensationERMSEmax
      Vacuum10000100001000011.00000.0431-0.05180.14400.04390.97740.01420.00950.02650.02610.8505-0.33770.01750.03510.33430.93011.00000.0487-0.0494-0.00190.04730.9899-0.0153-0.01430.0074-0.00710.9669-0.01060.03040.0431-0.06050.93140.03540.0686
      Polarizer 0°11001100000000001.00000.99220.00770.01290.98230.98200.0067-0.0048-0.03140.04050.04310.02860.0136-0.0157-0.01480.00351.00000.99430.02270.00940.98590.9838-0.0067-0.00580.01560.0003-0.06710.0537-0.02120.0070-0.0330-0.05970.01990.0471
      Polarizer 45°10100000101000001.00000.03621.2229-0.59370.0174-0.00430.0415-0.0556-0.1386-0.0399-0.1625-0.01541.39220.04921.4881-0.79761.00000.04110.99980.00800.0113-0.00610.00420.00351.05840.00561.0248-0.0449-0.00440.0332-0.04090.03240.02710.0584
      Quarter-wave plate 0°10000100000-100101.0000-20240.0630-0.07800.0266-0.0853-0.8329-0.30810.00130.42040.3130-0.62680.09580.9229-0.17800.74611.00000.0616-0.0022-0.06030.05840.98600.0181-0.00350.00140.04300.00411.01970.02360.0036-0.9539-0.06760.03890.0676
      Quarter-wave plate 90°10000100000-100101.00000.0564-0.16820.08250.04800.97690.01500.01020.00970.0028-0.4047-0.78830.00660.04000.8655-0.35181.00000.0651-0.02520.06120.05410.9911-0.01440.01260.0007-0.02430.0193-0.94520.00660.03190.96880.06300.03750.0630
      Half-wave plate 0°1000010000-10000-11.00000.08670.05370.16290.06760.98700.0020-0.0112-0.03230.0003-0.87320.3927-0.02600.0124-0.2852-0.93531.00000.06940.03940.01900.06250.99720.0020-0.0002-0.0054-0.0087-1.0308-0.0211-0.04080.00890.0340-0.95690.03250.0694
    • Table 3. Comparison of compensation results for different samples with 45° quarter-wave plate

      View table

      Table 3. Comparison of compensation results for different samples with 45° quarter-wave plate

      SampleTheoretical Mueller matrixExperimental Mueller matrix(with compensation)Mueller Matrix element error
      ERMSEmax
      Vacuum10000100001000011.00000.04540.0343-0.03810.04700.9905-0.0136-0.0137-0.0340-0.00760.97720.00860.04840.0406-0.07830.92810.03910.0783
      Polarizer 0°11001100000000001.00001.0015-0.03310.00760.98870.98590.0108-0.00390.00700.0156-0.04510.06980.02960.0231-0.0771-0.03650.03310.0698
      Half-wave plate 0°1000010000-10000-11.00000.0590-0.04900.05160.07070.99430.0066-0.00110.0383-0.0090-1.0275-0.0469-0.05340.01350.0423-0.95430.03960.0707
      Quarter-wave plate 0°10000100000-100101.00000.06580.03450.02940.05690.98700.0193-0.00240.01190.0418-0.01761.02810.06280.0074-0.9530-0.06350.03820.0658
    Tools

    Get Citation

    Copy Citation Text

    Shuqiang Huang, Xiumei Jiang, Yuanhua Feng. Analysis of Phase Error of Retarders in Spectrally Encoded Mueller Matrix Measurement[J]. Laser & Optoelectronics Progress, 2021, 58(19): 1926001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Physical Optics

    Received: Jan. 21, 2021

    Accepted: Feb. 12, 2021

    Published Online: Oct. 14, 2021

    The Author Email: Feng Yuanhua (favinfeng@163.com)

    DOI:10.3788/LOP202158.1926001

    Topics