Optics and Precision Engineering, Volume. 30, Issue 1, 1(2022)

Four-band coaxial imaging experimental platform and its image fusion methods

Zhihao LIU1... Weiqi JIN1,*, Li LI1, Mozhou SHA2 and Qin GUO2 |Show fewer author(s)
Author Affiliations
  • 1MoE Key Lab of Photoelectronic Imaging Technology and System, Shool of Optics and Photonics, Beijing Institute of Technology, Beijing0008, China
  • 2Beijng Electro-Mechanical Engineering Institute, Beijing100074, China
  • show less
    Figures & Tables(17)
    Four-band coaxial imaging optical system
    Four-band coaxial imaging experimental platform
    Four-band original images captured at the same time
    Preprocessed four-band images
    Flow chart of dual-band natural color fusion algorithm
    Dual-band natural color fusion images
    Flow chart of four-band natural color fusion algorithm
    Four-band natural color fusion images
    Q-T relationship curve
    Flow chart of dual-band temperature measurement software
    Temperature image generated by MW and LW IR images
    Single-point stability results of temperature measurement
    Result of experiment on the sea
    Result of experiment on the land
    • Table 1. Film design of semi-reflective mirror

      View table
      View in Article

      Table 1. Film design of semi-reflective mirror

      分束镜反射率参数(入射角为45°)透过率参数(入射角为45°)
      波段/μm反射率/%波段/μm反射率/%
      第一分束镜0.4~1.7>953~12>92
      第二分束镜3~5>988~12>92
      第三分束镜0.4~0.9>980.9~1.7>92
    • Table 2. Detector parameters of four-band coaxial imaging experimental platform

      View table
      View in Article

      Table 2. Detector parameters of four-band coaxial imaging experimental platform

      探测器波段分辨率像素尺寸工作波段NETD
      可见光+近红外1 280 H×1 024 V14 μm×14 μm0.4~1.1 μm-
      短波红外640 H×512 V15 μm×15 μm0.9~1.7 μm-
      中波红外640 H×512 V-3~14 μm≤40 mK@25 ℃,F#1.0
      长波红外640 H×512 V-8~14 μm≤40 mK@25 ℃,F#1.0
    • Table 3. Results of dual-band and single-band temperature measurement

      View table
      View in Article

      Table 3. Results of dual-band and single-band temperature measurement

      黑体

      温度/℃

      双波段测温/℃

      相对

      误差/%

      中波

      测温/℃

      长波

      测温/℃

      2019.661.7116.9117.49
      2525.150.6023.2923.16
      3031.013.3627.8228.85
      3535.892.5533.6333.74
      4040.160.4138.0641.49
      4545.290.6444.6946.02
      5049.630.7451.0251.41
      5555.060.1056.2956.62
      6060.530.8862.1761.67
      6565.711.0967.4066.93
      7070.540.7772.5971.94
      7576.712.2877.6877.30
      8081.732.1782.3482.55
    Tools

    Get Citation

    Copy Citation Text

    Zhihao LIU, Weiqi JIN, Li LI, Mozhou SHA, Qin GUO. Four-band coaxial imaging experimental platform and its image fusion methods[J]. Optics and Precision Engineering, 2022, 30(1): 1

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Modern Applied Optics

    Received: Aug. 27, 2021

    Accepted: --

    Published Online: Jan. 20, 2022

    The Author Email: JIN Weiqi (jinwq@bit.edu.cn)

    DOI:10.37188/OPE.20223001.0001

    Topics