Optics and Precision Engineering, Volume. 22, Issue 10, 2585(2014)

Cross-spectral calibration for monochromator and imaging spectrometer

CAO Hai-xia1,2、*, WU Na1, FENG Shu-long1, PAN Ming-zhong1, ZHANG Yong-chao1,2, and CUI Ji-cheng1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(17)

    [1] [1] YANG J,TANG Y G, BAYANHESHIG, et al.. Design of Dyson concentric optical hyperspectral imaging system with achromatized Fery prism[J]. Acta Optica Sinica ., 2012,32(11):113003.(in Chinese)

    [2] [2] QI X D, HAN P P, PAN M ZH, et al.. Spectral calibration of imaging spectrometer with convex grating[J]. Opt. Precision Eng.,2011,19(12):2871-2876.(in Chinese)

    [4] [4] BROWN T J, CORBETT F J, SPERA T J, et al.. Thermal infrared push broom imagery acquisition and processing[J]. SPIE, 1981,304:37-56.

    [5] [5] DINER D J, BRUEGGE C J, MARTONCHIK J V, et al.. MISR: a multiangle imaging spectroradiometer for geophysical and climatological research[J]. IEEE Trans. Geosci. Remote Sens.,1989,27:200-214.

    [6] [6] SAINTPE O, DONNADIEU O, DAVANCENS R, et al.. Development of a 2-D array for 1 to 2.35 mm hyperspectral imager[J]. SPIE, 1997,2816:138-149.

    [11] [11] THOMAS G C, ROBERT O G, MICHAEL L. Accuracy of the spectral and radiometric laboratory calibration of the airborne visible/infrared imaging spectrometer(AVIRIS)[J]. SPIE, 1990, 1298:37-49.

    [12] [12] AMOLD G T, FITZGERALD M F, GRANT P S, et al.. MODIS airborne simulator radiometric calibration [J]. SPIE, 1996, 2820: 56-66.

    [13] [13] LUSHALAN L, PETER J, DARREL G, et al.. Performance characterization of the hyperion imaging spectrometer instrument [J]. SPIE, 2004, 4135: 264-275.

    [14] [14] JERRY Z, DANIEL G, ROBERT M. Calibration procedures and measurements for the COMPASS hyperspectral imager[J]. SPIE, 2004, 5425: 182-188.

    [15] [15] WANG J Y. Spectral response and spectral resolution of hyperspectral imager[J].Imaging Spectrum.,1991,10:40-50.(in Chinese)

    [16] [16] WANG J Y. Analysis of the resolution of hyperspectral imager[J]. Infrared, 1990,9(4):277-286.(in Chinese)

    [17] [17] LIU Y J. The Study on Newly Imaging Spectrometers Based on Concentric Optics[D]. Beijing:Graduate University of the Chinese Academy of Sciences, 2012:93-107. (in Chinese)

    CLP Journals

    [1] XIA Zhi-wei, WANG Kai, FANG Wei, Wang Yu-peng. Applications and development of radiation calibration in orbit based on space monochromator[J]. Optics and Precision Engineering, 2015, 23(7): 1880

    Tools

    Get Citation

    Copy Citation Text

    CAO Hai-xia, WU Na, FENG Shu-long, PAN Ming-zhong, ZHANG Yong-chao, CUI Ji-cheng. Cross-spectral calibration for monochromator and imaging spectrometer[J]. Optics and Precision Engineering, 2014, 22(10): 2585

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jul. 8, 2013

    Accepted: --

    Published Online: Nov. 6, 2014

    The Author Email: Hai-xia CAO (caohaixia132@163.com)

    DOI:10.3788/ope.20142210.2585

    Topics