Acta Optica Sinica, Volume. 39, Issue 6, 0612008(2019)

Synchronous Measurement Methods for Particulate Matter and Gas Concentrations

Ciwei Chen, Bin Zhou*, Yangkun Zhu, Yihong Wang, and Weican Liang
Author Affiliations
  • School of Energy and Environment, Southeast University, Nanjing, Jiangsu 210096, China
  • show less
    Figures & Tables(14)
    Effect of scattering coefficient term on harmonic signal. (a) First harmonic signal; (b) second harmonic signal
    Simulated signal and gas concentration. (a) Normalized second harmonic signal; (b) relationship between measured gas concentration and real concentration
    Simulated signal and particle concentration after eliminating gas absorption effect. (a) First harmonic amplitude; (b) relationship between the mean of amplitudes and the mass concentration of particulate matter
    Schematic of experimental verification system based on light intensity modulation
    Measured original signal
    Spectrum measured by LIM
    Experimental measurement results. (a) First harmonic signal measured by LIM; (b) comparison of eigenvalue and value measured by dust meter
    Schematic of experimental system for synchronous measurement of gas and particle concentrations
    Experimental and verification results of WMS-LS method. (a) Normalized second harmonic amplitude; (b) comparison of water vapor volume fraction measured by WMS-LS with that by temperature-humidity sensor
    Amplitudes of first harmonic R1f of scattered light signals
    Experimental and verification results of WMS-LS method after eliminating gas absorption effect. (a) Amplitude of first harmonic; (b) comparison of mass concentration of particulate matter measured by WMS-LS with that by dust meter
    • Table 1. Measured spectroscopic parameters at 296 K

      View table

      Table 1. Measured spectroscopic parameters at 296 K

      υ0 /cm-1S0 /(cm-2·MPa-1)γself /(cm-1·MPa-1)γair /(cm-1·MPa-1)
      7185.600.1922.020.434
    • Table 2. Parameters for gas and particle concentration synchronously simultaneous measurement

      View table

      Table 2. Parameters for gas and particle concentration synchronously simultaneous measurement

      ParameterValue
      Scanning frequency /Hz100
      Modulation frequency /kHz10
      Scanning depth /cm-10.28
      Modulation depth /cm-10.08
      Smoke volume /m35×10-4
      Scattering angle /(°)15
      Particle density /(kg·m-3)500
      Particle diameter /μm2.5
      Particle refractive index1.33
      Scattering distance /m0.1
      Gas temperature /K298
      Total gas pressure /MPa0.1
      Path length /m0.4
    • Table 3. Experimental parameters for synchronous measurement of gas and particle concentrations

      View table

      Table 3. Experimental parameters for synchronous measurement of gas and particle concentrations

      Scanning frequency /HzSweep voltage /VModulation frequency /kHzModulating voltage /VSampling frequency /(MSa·s-1)
      1000.7100.51
    Tools

    Get Citation

    Copy Citation Text

    Ciwei Chen, Bin Zhou, Yangkun Zhu, Yihong Wang, Weican Liang. Synchronous Measurement Methods for Particulate Matter and Gas Concentrations[J]. Acta Optica Sinica, 2019, 39(6): 0612008

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Jan. 17, 2019

    Accepted: Mar. 21, 2019

    Published Online: Jun. 17, 2019

    The Author Email: Zhou Bin (zhoubinde@seu.edu.cn)

    DOI:10.3788/AOS201939.0612008

    Topics