Acta Optica Sinica, Volume. 39, Issue 6, 0628004(2019)

Novel Portable Sensor for Simultaneous Monitoring of Oxygen and Temperature

Huimin Cao1,2,3、*, Faguang Li1,2,3, Lerong Dai1,2,3, Chao Wu1,2,3, Dongyun Zheng1,2,3, and Chunnan Zhu1,2,3
Author Affiliations
  • 1 College of Biomedical Engineering, South-Central University for Nationalities, Wuhan, Hubei 430074, China
  • 2 Key Laboratory of Brain Cognitive Science, State Ethnic Affairs Commission, South-Central University for Nationalities, Wuhan, Hubei 430074, China
  • 3 Hubei Key Laboratory of Medical Information Analysis & Tumor Diagnosis and Treatment, Wuhan, Hubei 430074, China;
  • show less
    Figures & Tables(13)
    Schematics of sensors. (a) 2 μL AFC film; (b) 2 μL PtTFPP film; (c) 2 μL Rh110 film; (d) 2 μL mixed film; (e) without film
    Dual-sensor performance detection device
    Block diagram of hardware function of sensing system
    Fluorescence spectra of PtTFPP, AFC, and Rh110 at room temperature
    Fluorescence quenching response spectra of oxygen-sensitive material
    Fluorescence quenching response spectra of temperature-sensitive material
    Relationship between fluorescence intensity ratio and oxygen concentration
    Relationship between fluorescence intensity ratio and temperature
    Relationship between fluorescence intensity and oxygen concentration under different temperatures
    • Table 1. Experimental reagents and related parameters

      View table

      Table 1. Experimental reagents and related parameters

      ReagentSupplierPurity
      PtTFPPAlfa Aesar≥99.0%
      Rh110Alfa Aesar≥99.0%
      AFCSigma-Alorich≥99.0%
      TEOSSinopharm Chemical≥95.0%
      Octyl-tri EOSSinopharm Chemical≥95.0%
      TESPICSinopharm Chemical≥95.0%
      Triton-X-100Wuhan ShenshiChemical pure
      THFWuhan ShenshiAnalytical pure
    • Table 2. List of experimental instruments

      View table

      Table 2. List of experimental instruments

      InstrumentSpecification typeProducer
      Magnetic heating stirrer79-2Jintan China
      Digital ultrasonic cleanerKQ3200DBKunshan China
      CentrifugeD-37520Wuhan China
      Rotary evaporatorRE-52AAShanghai China
      Fluorescence spectrophotometerF-7000Hitachi High-Technologies
      Electron microscopesSU8010Hitachi High-Technologies
    • Table 3. Measurement value and accuracy of oxygen concentration

      View table

      Table 3. Measurement value and accuracy of oxygen concentration

      Standard value /%36912151821242730
      Measured value /%2.885.719.3211.5815.2318.3921.3624.4127.2230.15
      Bias /%-4.00-4.833.563.501.532.171.711.710.810.50
    • Table 4. Measurement value and accuracy of temperature

      View table

      Table 4. Measurement value and accuracy of temperature

      Standard value /℃515253545556575
      Measured value /℃4.1214.2624.8634.1746.8356.2463.8572.85
      Bias /%-17.60-4.93-0.56-2.374.072.25-1.77-2.87
    Tools

    Get Citation

    Copy Citation Text

    Huimin Cao, Faguang Li, Lerong Dai, Chao Wu, Dongyun Zheng, Chunnan Zhu. Novel Portable Sensor for Simultaneous Monitoring of Oxygen and Temperature[J]. Acta Optica Sinica, 2019, 39(6): 0628004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Dec. 12, 2018

    Accepted: Mar. 7, 2019

    Published Online: Jun. 17, 2019

    The Author Email: Cao Huimin (huimincao@mail.scuec.edu.cn)

    DOI:10.3788/AOS201939.0628004