High Power Laser and Particle Beams, Volume. 36, Issue 9, 093003(2024)

Analysis of the influence of key parameters of step-frequency radar on false alarm signal

Xue Du... Guanghui Wei* and Dalin Wu |Show fewer author(s)
Author Affiliations
  • Army Engineering University (Shijiazhuang Campus), Shijiazhuang 050003, China
  • show less
    Figures & Tables(11)
    Block diagram of field configuration
    Test radar terminal control software
    Single frequency interference target range imaging
    Imaging of false alarm signal with different frequency hopping time
    Test results of false alarm level under different frequency hopping intervals
    • Table 1. Test data of false alarm signal under different interference strengths

      View table
      View in Article

      Table 1. Test data of false alarm signal under different interference strengths

      U1/dBmVR1/mU2/dBmVR2/m
      E1=6 dBV/mE2=17.5 dBV/m
      19.124506.020.704586.0
      19.103330.020.802756.0
      19.132769.020.733580.0
      19.121384.020.682860.0
      19.13633.720.73932.9
      19.123256.020.703456.0
      19.103344.020.663243.0
      19.121819.020.702016.0
      19.13783.720.71689.3
      19.001123.020.684586.0
    • Table 2. False alarm signal test data (E1=20.6 dBV/m)

      View table
      View in Article

      Table 2. False alarm signal test data (E1=20.6 dBV/m)

      tr/msn'Um/dBmVR/mΔR
      0.05124.672077.0
      0.04418.5419.2ΔR1=1519.8 m
      18.51939.0ΔR2=1517.0 m
      18.33456.0ΔR3=1490.0 m
      18.44946.0ΔR1508.0 m
      0.03319.21364.0ΔR1=1504.0 m
      19.22868.0ΔR2=1518.0 m
      19.24386.0ΔR1511.0 m
      0.02219.61155.0ΔR1502.0 m
      19.52657.0
      0.01117.7965.1
    • Table 3. False alarm signal test data (E2=32.6 dBV/m)

      View table
      View in Article

      Table 3. False alarm signal test data (E2=32.6 dBV/m)

      tr/msn'Um/dBmVR/mΔR
      0.05124.82033.0
      0.04418.6242.9ΔR1=1499.1 m
      18.61742.0ΔR2=1503.0 m
      18.73245.0ΔR3=1494.0 m
      18.64739.0ΔR1498.7 m
      0.03319.2713.6ΔR1=1496.4 m
      19.32210.0ΔR2=1514.0 m
      19.23724.0ΔR1510.2 m
      0.02219.41402.0ΔR1501.0 m
      19.52903.0
      0.01117.7553.4
    • Table 4. False alarm signal test data (Δf2=40 MHz)

      View table
      View in Article

      Table 4. False alarm signal test data (Δf2=40 MHz)

      tr/msn'Um/dBmVR/mΔR
      注:表中ΔR1、ΔR2、ΔR3分别代表出现多虚警目标时,第n′个和第n′+1个(n′=1,2,3)之间的间隔,ΔR表示对间隔取平均。
      0.05121.231983.0
      0.04414.6500.9ΔR1=1498.1 m
      14.81999.0ΔR2=1503.0 m
      14.93502.0ΔR3=1495.0 m
      14.64997.0ΔR1498.7 m
      0.03314.8609.6ΔR1=1493.7 m
      15.02103.0ΔR2=1497.0 m
      15.03600.0ΔR1495.4 m
      0.02215.0383.9ΔR1504.0 m
      15.11888.0
      0.01113.2499.4
    • Table 5. False alarm signal test data (Δf*=10 kHz,Δf2=0 MHz)

      View table
      View in Article

      Table 5. False alarm signal test data (Δf*=10 kHz,Δf2=0 MHz)

      tr/msn'ΔR/mU1/dBmV
      E1=17.6 dBV/mE1=20.6 dBV/mE1=26.6 dBV/m
      0.05120.720.921.1
      0.042300016.917.317.1
      0.033150014.714.914.8
      0.02118.218.118.4
      0.01113.913.713.9
    • Table 6. False alarm signal test data (Δf*=10 kHz,Δf2=−60 MHz)

      View table
      View in Article

      Table 6. False alarm signal test data (Δf*=10 kHz,Δf2=−60 MHz)

      tr/msn'ΔR/mU2/dBmV
      E2=17.6 dBV/mE2=20.6 dBV/mE2=26.6 dBV/m
      0.05117.117.217.4
      0.042300013.613.713.8
      0.033150011.210.711.1
      0.02114.014.414.6
      0.0119.39.810.5
    Tools

    Get Citation

    Copy Citation Text

    Xue Du, Guanghui Wei, Dalin Wu. Analysis of the influence of key parameters of step-frequency radar on false alarm signal[J]. High Power Laser and Particle Beams, 2024, 36(9): 093003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 3, 2024

    Accepted: Jul. 13, 2024

    Published Online: Oct. 15, 2024

    The Author Email: Wei Guanghui (wei-guanghui@sohu.com)

    DOI:10.11884/HPLPB202436.240072

    Topics