Optics and Precision Engineering, Volume. 19, Issue 3, 552(2011)

Measurement and correction of stray light of space-borne high resolution imaging spectrometer

ZHANG Jun-qiang1...2,*, WU Qing-wen1 and YAN Chang-xiang1 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(22)

    [1] [1] SHI G H. Mathods preventing stray light emergenced in Cassegrain systems[J]. Opt. Precision Eng., 1997,5(5):10-16. (in Chinese)

    [4] [4] ZHANG G Y, LI F CH, GAO Y J. Theoretical study of stray light black-spot measurement for optical system[J]. Optical Technology, 1997,2:35-38. (in Chinese)

    [5] [5] YU B X. The stray light in monochromator and its measurement[J]. Acta Metrologica Sinica, 1991,12(3):177-180. (in Chinese)

    [6] [6] YU Y, HOU X Q. Analysis and measurement of stray light in non-monochromatic spectrometer[J]. Application Optics, 1991,12(5):53-56. (in Chinese)

    [8] [8] CUTTER M A, LOBB D R, WILLIAMS T L, et al.. Integration & testing of the compact high-resolution imaging spectrometer (CHRIS) [J]. SPIE, 1999,3753:180-191.

    [9] [9] STUFFLER T, KAUFMANNB C, HOFEREA S, et al.. The EnMAP hyperspectral imager-An advanced optical payload for future applications in Earth observation programmes[J]. Acta Astronautica, 2007,61:115-120.

    [12] [12] DU B L, LI L, HUANG Y F, et al.. Analysis and study on coating suppressing stray-light of space remote sensor[J]. Acta Photonica Sinica, 2009,37:220-222. (in Chinese)

    [17] [17] ZONG Y,BROWN S W, JOHNSON B C, et al.. Correction of stray light in spectrographs: implications for remote sensing[J]. SPIE, 2005,5882:1-8.

    [18] [18] ZONG Y,BROWN S W, JOHNSON B C, et al.. Simple spectral stray light correction method for array spectroradiometers[J]. Appl. Opt., 2006,45(6):1111-1119.

    [19] [19] ZONG Y,BROWN S W,JOHNSON B C, et al.. Correction of stray light in spectroradiometers and imaging instruments[J]. CIE, 2007,178(D2):33-36.

    [20] [20] ZONG Y, BROWN S W,MEISTER G, et al.. Characterization and correction of stray light in optical instruments[J]. SPIE, 2007,6744:67441L-1- 67441L-11.

    [21] [21] ZHAO Y J, TANG M X, WU J H. A method for enhancing SNR of linear CCD in spectroscopy[J]. Optoelectronic Technology & Information, 2004,17(4):43-46. (in Chinese)

    CLP Journals

    [1] Wu Yue, Liu Jiaxiang, Fang Yonghua, Zhang Leilei, Yang Wenkang. Background radiation analysis and suppression of C-T type planar waveguide infrared spectrometer system[J]. Infrared and Laser Engineering, 2019, 48(8): 803001

    [2] ZHOU Hai-jin, LIU Wen-qing, SI Fu-qi, JIANG Yu, XUE Hui. Stray light suppression of space-borne differential optical absorption spectrometer for monitoring atmospheric trace gas[J]. Optics and Precision Engineering, 2012, 20(11): 2331

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Jun-qiang, WU Qing-wen, YAN Chang-xiang. Measurement and correction of stray light of space-borne high resolution imaging spectrometer[J]. Optics and Precision Engineering, 2011, 19(3): 552

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 31, 2009

    Accepted: --

    Published Online: Mar. 30, 2011

    The Author Email: Jun-qiang ZHANG (zjq1981_81@163.com)

    DOI:

    CSTR:32186.14.

    Topics