Acta Photonica Sinica, Volume. 35, Issue 11, 1717(2006)
Spectra Study on the Quality Change of Deep Frying Edible Oils by Synchronous Scan Fluorescence Spectra
Unfried and fried oils were analyzed and studied by synchronous scan fluorescence spectra and combined with infrared absorption spectra. Synchronous scan fluorescence gave a narrower and simpler spectrum and was of extensive use for multi-fluorescence analysis. In this method,both excitation and emission monochromators were scanned simultaneously keeping a fixed wavelength interval (△λ) between them ( constant △λ mode). In experiment,the optimization △λ was 10 nm. The synchronous scan fluorescence was obtained in the emission wavelength range of 250 nm~700 nm. Compared with fresh oils,in the fluorescence spectra image of fried oils,fluorescence peak value in 370~380 nm disappeared,and two fluorescence peak value in 461 nm and 479 nm emerged. In 1745 cm-1,the intensity of infrared absorption increased. All of this indicate that the number of carbonyl ( C = O) increased,which was the same to chromatogram approximately.
Get Citation
Copy Citation Text
Jia Yanhua, Xu Xiaoxuan, Yang Renjie, Liang Jun, Zhou Xinyong, Zhang Cunzhou. Spectra Study on the Quality Change of Deep Frying Edible Oils by Synchronous Scan Fluorescence Spectra[J]. Acta Photonica Sinica, 2006, 35(11): 1717
Category:
Received: Jul. 8, 2005
Accepted: --
Published Online: Jun. 3, 2010
The Author Email: Yanhua Jia (jiayh@mail.nankai.edu.cn)
CSTR:32186.14.