Infrared and Laser Engineering, Volume. 53, Issue 8, 20240168(2024)

Design and research of LD pulse pumped Er3+/Yb3+:Lu2Si2O7 crystal 100 kHz laser

Jianing PENG1, Xue HAN1, Xiaolu NIE1, Xiang GAO1, Zhanda ZHU1,2, Hong LEI1,2, and Qiang LI1,2
Author Affiliations
  • 1Institute of Laser Engineering, College of Physics and Optoelectronic Engineering, Beijing University of Technology, Beijing 100124, China
  • 2Beijing Engineering Research Center of Laser Technology, Beijing 100124, China
  • show less
    Figures & Tables(8)
    The device diagram of passive Q-switched laser. (a) Collimating focusing lens combination; (b) Single focusing lens
    Free oscillating output power at different transmittance of output mirrors
    Free oscillating output power at different transmittance of output mirrors
    100 kHz output pulse waveform. (a) Duty cycle 30%; (b) Duty cycle 70%
    Pulse performance for 100 kHz. (a) Pump waveform and output laser pulse train; (b) Pulse width figure; (c) Output laser spectra; (d) Far field facula and beam quality measurement diagram
    • Table 1. Optimization of pump beam diameter for 100 kHz

      View table
      View in Article

      Table 1. Optimization of pump beam diameter for 100 kHz

      $ F\mathrm{_{focus}} $/mm$ {\omega }_{p} $/μm$ {f}_{p} $/kHz$ {T}_{Q} $$ {T}_{OC} $$ {\tau }_{P} $/μs$ {E}_{p} $/μJ$ f_0 $/kHz$ E_0 $/μJ
      4013010099%10%3271000.7
      32400.5
      43000.6
      5350<100
    • Table 2. Repeated frequency and energy instability measured under different duty cycles

      View table
      View in Article

      Table 2. Repeated frequency and energy instability measured under different duty cycles

      Power/WDuty cycleRepeated frequency instabilityEnergy instability
      930%0.03450.1551
      7.7235%0.03720.1926
      6.7540%0.03910.2261
      645%0.04310.2746
      5.450%0.04460.3172
      4.955%0.04610.3631
      4.560%0.05130.3978
      4.1565%0.05200.4339
      3.8570%0.05660.4842
    • Table 3. Optimization of initial transmittance of Co2+:MgAl2O4 for 100 kHz

      View table
      View in Article

      Table 3. Optimization of initial transmittance of Co2+:MgAl2O4 for 100 kHz

      $ {f}_{p} $/kHz$ {T}_{Q} $$ {\omega }_{p} $/μm$ {T}_{OC} $$ {\tau }_{P} $/μs$ {E}_{p} $/μJ$ f_0 $/kHz$ E_0 $/μJ$ \tau_0 $/ns
      10095.8%13010%327<100
      99%1000.7240
      99.7%0.5270
    Tools

    Get Citation

    Copy Citation Text

    Jianing PENG, Xue HAN, Xiaolu NIE, Xiang GAO, Zhanda ZHU, Hong LEI, Qiang LI. Design and research of LD pulse pumped Er3+/Yb3+:Lu2Si2O7 crystal 100 kHz laser[J]. Infrared and Laser Engineering, 2024, 53(8): 20240168

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Apr. 19, 2024

    Accepted: --

    Published Online: Oct. 29, 2024

    The Author Email:

    DOI:10.3788/IRLA20240168

    Topics