Acta Photonica Sinica, Volume. 39, Issue 1, 105(2010)

A Method of Bifocal Zoom Endoscope System Design

ZHANG Wei1...2,*, TIAN Weijian1,2, and ZHANG Hong-jian12 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less
    References(13)

    [1] [1] LI Jing-yan,LIU De-sen,LIU Gang,et al. The application and trend of development of the medical endoscope system[J]. Medical Instrument,2005,18(7): 9-11.

    [2] [2] CAO Chang-jiang,ZHANG Chen,ZHANG Kai-bin. The Research on Medical Endoscope Surveillance System Based Oil Micro-motor[J].Instrument Technique and Sensor,2001,4: 34-36.

    [3] [3] REN H,FAN Y,GAUZA S,et al. Tunable-focus flat liquid crystal spherical lens[J]. Appl Phys Lett,2004,84(23): 4789-4791.

    [4] [4] BAIRD J L G,LIN Y H,REN H,et al. Refractive-index matching between liquid crystals and photopolymers[J].Soc Info Display,2005,13: 1017-1026.

    [5] [5] ZHANG De-ying,VICTOR L,YEVGENY B,et al. Fluidic adaptive lens with high focal length tenability[J]. Appl Phys Lett,2003,82(19): 3171-3172.

    [6] [6] KUIPER S,HENDRIKS B H W. Variable-focus lens for miniature cameras[J]. Appl Phys Lett,2004,85(7): 100-109.

    [7] [7] KRUPENKIN T,YANG S,MACH P,Tunable liquid microlens[J]. Appl Phys Lett,2002,82(3): 1128-1130.

    [8] [8] REN H,WU T. Variable-focus liquid lens by changing aperture[J]. Appl Phys Lett,2005,86(21): 211107-1-3.

    [9] [9] REN H,DAVID F,ANDERSON P A,et al. Tunable-focus liquid lens controlled using a servo motor[J]. Opt Express,2006,14(18): 8031-8036.

    [10] [10] BAO Yun,TIAN Wei-jian,ZHANG Wei. Hybrid diffractive-refractive liquid lens for variable-focus optical system[J]. Acta Photonica Sinica,2007,36(Sup) : 145-148.

    [11] [11] ZHANG Wei,ZHANG Hong-jian,TIAN Wei-jian. Wide tunable-focus liquid lens design by mechanical driving method[J]. Journal of Applied Optics,2008,29(Sup): 59-63.

    [13] [13] BORN M,WOLF E. Principles of optics[M]. YANG Jia-sun,transl. 7th ed. Beijing: Publishing House of Electronics Industry,2005.

    CLP Journals

    [1] GUO Xin, ZHANG Wei, SU Jin-hui, YANG Bo, WAN Xin-jun. Design of a Focus-tunable Capsule Endoscope System[J]. Acta Photonica Sinica, 2015, 44(5): 522004

    [2] DU Li-hui, WANG Li-qiang, YANG Tian-ling, LU Zu-kang, DUAN Hui-long. Miniature Telecentric Confocal Laser Scanning Endomicroscopy[J]. Acta Photonica Sinica, 2011, 40(12): 1767

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Wei, TIAN Weijian, ZHANG Hong-jian. A Method of Bifocal Zoom Endoscope System Design[J]. Acta Photonica Sinica, 2010, 39(1): 105

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 6, 2008

    Accepted: --

    Published Online: Mar. 11, 2010

    The Author Email: Wei ZHANG (zhw@opt.ac.cn)

    DOI:10.3788/gzxb20103901.0105

    Topics