Optoelectronics Letters, Volume. 18, Issue 2, 91(2022)

Roll angle of autocollimator measurement method based on hollow cube corner reflector

Yu LIU1... Yan ZHEN1, Linyi XIE1, Wei WANG2, Jiawen YANG1 and Renpu LI1,* |Show fewer author(s)
Author Affiliations
  • 1Chongqing Engineering Research Center of Intelligent Sensing Technology and Microsystem, Chongqing University of Post and Telecommunications, Chongqing 400065, China
  • 2School of Biology, Chongqing University of Posts and Telecommunications, Chongqing 400065, China
  • show less
    References(15)

    [1] [1] GAO W, KIM S W, BOSSE H, et al. Measurement technologies for precision positioning[J]. CIRP annals, 2015, 64(2):773-796.

    [2] [2] GILLMER S R, YU X Z, WANG C, et al. Robust high-dynamic-range optical roll sensing[J]. Optics letters, 2015, 40(11):2497-2500.

    [3] [3] ZHU F, TAN J B, CUI J W. Common-path design criteria for laser datum based measurement of small angle deviations and laser autocollimation method in compliance with the criteria with high accuracy and stability[J]. Optics express, 2013, 21(9):11391-11403.

    [4] [4] D'AMBROSIO V, SPAGNOLO N, DEL RE L, et al. Photonic polarization gears for ultra-sensitive angular measurements[J]. Nature communications, 2013, 4(1): 222-229.

    [5] [5] CUI C X, FENG Q B, ZHANG B, et al. System for simultaneously measuring 6DOF geometric motion errors using a polarization maintaining fiber-coupled dual-frequency laser[J]. Optics express, 2016, 24(6): 6735-6748.

    [6] [6] SERGEEV S A, MESHALKIN A Y, IOVU M S. Diffraction structures formed by two crossed superimposed diffraction gratings[J]. Surface engineering and applied electrochemistry, 2021, 57(2):207-216.

    [7] [7] HSU C C, CHEN H, TSENG H Y, et al. High displacement resolution encoder by using triple grating combination interferometer[J]. Optics and laser technology, 2018, 105:221-228.

    [8] [8] HUANG J H, WANG Z, GAO J M, et al. Modeling and analysis of phase fluctuation in a high-precision roll angle measurement based on a heterodyne interferometer[J]. Sensors, 2016, 16(8):1214.

    [9] [9] GECKELER R D, KRANZ O, JUST A, et al. A novel approach for extending autocollimator calibration from plane to spatial angles[J]. Advanced optical technologies, 2012, 1(6):427-439.

    [10] [10] REN W R, CUI J W, TAN J B. A novel enhanced roll-angle measurement system based on a transmission grating autocollimator[J]. IEEE access, 2019, 7: 120929-120936.

    [11] [11] ZHAI Y S, FENG Q B, ZHANG B. A simple roll measurement method based on a rectangular-prism[J]. Optics and laser technology, 2011, 44(4):839-843.

    [12] [12] QI J Y, WANG Z, HUANG J H, et al. Heterodyne interferometer with two parallel-polarized input beams for high-resolution roll angle measurement[J]. Optics express, 2019, 27(10):13820-13830.

    [13] [13] CAI Y D, YANG B H, FAN K C. Robust roll angular error measurement system for precision machines[J]. Optics express, 2019, 27(6):8027-8036.

    [14] [14] REN W R, CUI J W, TAN J B. Parallel beam generation method for a high-precision roll angle measurement with a long working distance[J]. Optics express, 2020, 28(23):34489-34500.

    [15] [15] LI R P, ZHEN Y, DI K, et al. Three-degree-of-freedom autocollimator with large angle-measurement range[J]. Measurement science and technology, 2021, 32(11): 115005.

    Tools

    Get Citation

    Copy Citation Text

    LIU Yu, ZHEN Yan, XIE Linyi, WANG Wei, YANG Jiawen, LI Renpu. Roll angle of autocollimator measurement method based on hollow cube corner reflector[J]. Optoelectronics Letters, 2022, 18(2): 91

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Jul. 9, 2021

    Accepted: Aug. 9, 2021

    Published Online: Jan. 20, 2023

    The Author Email: Renpu LI (lirp@cqupt.edu.cn)

    DOI:10.1007/s11801-022-1114-x

    Topics