Acta Photonica Sinica, Volume. 35, Issue 4, 587(2006)

Influence of Detector on Resolution in Confocal Imaging System

Ge Huayong1,*... Wang Baohua2 and Ren Qiushi3 |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less
    References(14)

    [1] [1] Minsky M. Microscopy apparatus. USA Patent,30133467.1961

    [2] [2] Wilson T. Confocal microscopy. London: Academic Press,1990.1~78,123~156

    [3] [3] Gu M. Principles of three-dimensional imaging in confocal microscopes. Singapore: World Scientific Publishing Co. Pte. Ltd,1996.1~174

    [4] [4] Wilson T,Sheppard C J R. Imaging and super-resolution in the harmonic microscope. Opt Acta,1979,26 (8) :761~770

    [5] [5] Gu M,Sheppard C J R. Three-demensional coherent transfer functions for confocal imaging with unequal annular lenses. J of Modern Opt,1993,40(7): 1255~1272

    [6] [6] Yang C P,Tang Z L,Pei H J. Imaging analysis of two-photon confocal microscopy with different fluorescence wavelength. Acta Photonica Sinica,2004,33 (2) : 159~163

    [7] [7] Gao W R,Tao C K,ang X C. Relationship between the two dimensional resolution and signal-to-noise ratio of laser confocal microscopy. Acta Photonica Sinica,2002,31(6):730~735

    [8] [8] Qi Y J,Chi Z Y,Chen W J,et al. The further studying of PSF in confocal scanning microscopy system. Acta Photonica Sinica,2002,31(8):1029~1031

    [9] [9] Fu L,Luo Q M,Lu Q,et al. Effect of sattering and absorption properties of bidogical tissue on two-photon excitation and confocal imaging depth. Acta Photonica Sinica,2001,30(3) : 262~266

    [10] [10] Wilson T,Carlini A R. Size of the detector in confocal imaging system. Opt Lett,1987,12(4): 227~229

    [11] [11] Gu M,Sheppard C J R. Three-dimensional partiallycoherent image formation in confocal microscopes with a finite-sized detector. J of Modern Opt,1994,41 (9)1701~1715

    [12] [12] Drazic V. Three-dimensional transfer function analysis of a confocal fluorescence microscope with a finite-sized source and detector. J of Modern Opt,1993,40(5):879~887

    [13] [13] Wilson T,Sheppard C R J. Theory and practice of scanning optical microscopy. London: Academic Press,1984.42~78

    [14] [14] Sheppard C J R,Wilson T. Image formation in scanning microscopes with partially coherent source and detector. Optica Acta,1978,25(4) :315~325

    Tools

    Get Citation

    Copy Citation Text

    Ge Huayong, Wang Baohua, Ren Qiushi. Influence of Detector on Resolution in Confocal Imaging System[J]. Acta Photonica Sinica, 2006, 35(4): 587

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jan. 6, 2005

    Accepted: --

    Published Online: Jun. 3, 2010

    The Author Email: Huayong Ge (huayongge@yahoo.com.cn)

    DOI:

    CSTR:32186.14.

    Topics