High Power Laser and Particle Beams, Volume. 33, Issue 4, 044006(2021)

Structural optimization design for beam position monitor support of High Energy Photon Source

Anxin Wang1...2, Zihao Wang1, Huizhou Ma1, Chunhua Li1,3, Xiaojun Nie1,2, Jiaxin Chen1,2, Donghui Zhu1,2, Jiebing Yu1,2, Huayan He1,2, Guangyuan Wang1,2, Yongji Yu1,2, Renhong Liu1,2, Junsong Zhang1,2, Ruiyang Qiu1,2, Lei Liu1,2, and Ling Kang12 |Show fewer author(s)
Author Affiliations
  • 1Institute of High Energy Physics, Chinese Academy of Sciences, Beijing 100049, China
  • 2Spallation Neutron Source Science Center, Dongguan 523803, China
  • 3University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(21)
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    [in Chinese]
    • Table 1. [in Chinese]

      View table
      View in Article

      Table 1. [in Chinese]

      materialcoefficient of thermal expansion / ℃−1Poisson’s ratiomodulus of elasticity / GPadensity / (kg·m3)
      Invar 4J320.63×10−60.231458140
      SUS 3041.7×10−50.311937750
      concrete1.4×10−50.18302300
    • Table 2. [in Chinese]

      View table
      View in Article

      Table 2. [in Chinese]

      simulation natural frequency / Hz
      1st(longitudinal) 2nd(lateral)
      ground bolt38.7107.4
      part grout63.8132.5
      full grout66.7135.9
    • Table 3. [in Chinese]

      View table
      View in Article

      Table 3. [in Chinese]

      fixation modeexperimental natural frequency / Hzsimulation error/%
      1st(longitudinal) 2nd(lateral) 1st(longitudinal) 2nd(lateral)
      ground bolt16.948.4129122
      part grout55.51041527
      full grout61.8107827
    • Table 4. [in Chinese]

      View table
      View in Article

      Table 4. [in Chinese]

      stiffness / N·m·rad−1simulation natural frequency / Hzsimulation error/%
      1st(longitudinal) 2nd(lateral) 1st(longitudinal) 2nd(lateral) 1st(longitudinal) 2nd(lateral)
      ground bolt2.3×1052.2×10616.848.50.60.2
      part grout9×1062.1×10755.5103.500.5
      full grout3.4×1072.5×10761.9107.10.20.1
    • Table 5. [in Chinese]

      View table
      View in Article

      Table 5. [in Chinese]

      measurementsimulation
      longitudinallaterallongitudinallateral
      ground/ nm BPM support/nm ratioground/ nm BPM support/nm ratioground/ nm BPM support/nm ratioground/ nm BPM support/nm ratio
      full grout19.562.83.2223.729.41.2419.547.62.4423.727.31.15
      part grout22.682.493.6523.329.61.2722.659.42.6323.327.31.17
    Tools

    Get Citation

    Copy Citation Text

    Anxin Wang, Zihao Wang, Huizhou Ma, Chunhua Li, Xiaojun Nie, Jiaxin Chen, Donghui Zhu, Jiebing Yu, Huayan He, Guangyuan Wang, Yongji Yu, Renhong Liu, Junsong Zhang, Ruiyang Qiu, Lei Liu, Ling Kang. Structural optimization design for beam position monitor support of High Energy Photon Source[J]. High Power Laser and Particle Beams, 2021, 33(4): 044006

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Particle Beams and Accelerator Technology

    Received: Oct. 29, 2020

    Accepted: --

    Published Online: Jun. 24, 2021

    The Author Email:

    DOI:10.11884/HPLPB202133.200297

    Topics