Optics and Precision Engineering, Volume. 17, Issue 9, 2218(2009)

Design of biochemical sensor based on high-Field Asymmetric Ion Mobility Spectrometry

LI Hua*... WANG Xiao-hao, TANG Fei and LIN Zhen-xiang |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(16)

    [1] [1] STEINER W E,HARDEN C S. Detection of aqueous phase chemical warfare agent degradation products by negative mode ion mobility time-of-flight mass spectrometry [J]. J. Am. Soc. Mass. Spectrom.,2006,17(2):241-245.

    [2] [2] MYLESA L,MEYERSA T P,ROBINSONB L. Atmospheric ammonia measurement with an ion mobility spectrometer [J]. Atmos. Environ.,2006,40(30):5745-5752.

    [3] [3] ERICKSON R P,TRIPATHI A,MASWADEH W M. Closed tube sample introduction for gas chromatography-ion mobility spectrometry analysis of water contaminated with a chemical warfare agent surrogate compound [J]. Anal. Chim. Acta.,2006,556(2):455-461.

    [4] [4] GUEVREMONT R,PURVES R. Comparison of experimental and calculated peak shapes for three cylindrical geometry FAIMS prototypes of differing[J]. J. Am. Soc. Mass Spectrom.,2005,16(3):349-362.

    [5] [5] GUEVREMONT R. High-field asymmetric waveform ion mobility spectrometry: a new tool for mass spectrometry [J]. J. Chromatogr.A,2004,1058(1-2):3-19.

    [6] [6] EICEMAN G A,NAZAROV E G,MILLER R A. A micro-machined ion mobility spectrometer-mass spectrometer [J]. IJIMS,2000,1(3):15-27.

    [7] [7] EICEMAN G A,KRYLOV E V,TADJIKOV B,et al.. Differential mobility spectrometry of chlorocarbons with a micro-fabricated drift tube [J]. Analyst,2004,129:297-304.

    [8] [8] EICEMAN G A,TADJIKOV B,et al.. Miniature radio-frequency mobility analyzer as a gas chromatographic detector for oxygen-containing volatile organic compounds,pheromones and other insect attractants [J]. J. Chromatogr.,A 2001,917:205-217.

    [9] [9] KRYLOV E V. A method of reducing diffusion losses in a drift spectrometer [J]. Tech. Phys.,1999,44(1):113-116.

    [10] [10] GUEVREMONT R,BARNETT D A,PURVES R W,et al.. Calculation of ion mobilities from electrospray ionization high-field asymmetric waveform ion mobility mass spectrometry data [J]. J. Chem. Phys.,2001,114(23):10270-10277.

    [11] [11] BURYAKOV I A,KOLOMIETS Y N,LUPPU B V. Detection of explosive vapors in the air using an ion drift nonlinearity spectrometer [J]. J. Anal. Chem.,2001,56(4):336-340.

    [12] [12] BURYAKOV I A. Qualitative analysis of trace constituents by ion mobility increment spectrometer [J]. Talanta,2003,61(33):369-375.

    [13] [13] KRYLOV E V,NAZAROV EG,MILLER R A,et al.. Field dependence of mobilities for gas-phase-protonated monomers and proton-bound dimers of ketones by planar field asymmetric waveform ion mobility spectrometer (PFAIMS) [J]. J. Phys.Chem. A,2002,106(22):5437-5444.

    [14] [14] KRYLOV EV. Pulses of special shapes formed on a capacitive load [J]. Instrum Exp.Tech.,1997,40:628-631.

    [15] [15] GUEVREMONT R,PURVES R W. Atmospheric pressure ion focusing in a high-field asymmetric waveform ion mobility spectrometer [J]. Rev. Sci. Instrum.,1999,70(2):1370-1383.

    [16] [16] PAPANASTASIOU D,WOLLNIK H,RICO G. Differential mobility separation of Ions using a rectangular asymmetric waveform [J]. J. Phys. Chem. A.,2008,112(16):3638-3645

    Tools

    Get Citation

    Copy Citation Text

    LI Hua, WANG Xiao-hao, TANG Fei, LIN Zhen-xiang. Design of biochemical sensor based on high-Field Asymmetric Ion Mobility Spectrometry[J]. Optics and Precision Engineering, 2009, 17(9): 2218

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Dec. 7, 2008

    Accepted: --

    Published Online: Oct. 28, 2009

    The Author Email: Hua LI (huali@mail.tsinghua.edu.cn)

    DOI:

    CSTR:32186.14.

    Topics