Acta Optica Sinica, Volume. 39, Issue 10, 1011003(2019)

Source Simulation Experimental System Based on Digital Micromirror Device

Xueqi Chen1,2、* and Aimin Jiang1,2、**
Author Affiliations
  • 1Space and Astronomical Technology Laboratory, National Astronomical Observatories, Chinese Academy of Sciences, Beijing 100101, China
  • 2University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(14)
    Structural diagram of source simulation system based DMD
    Imaging performance of experimental system. (a) MTF curve; (b) field curvature and distortion
    DMD's azimuth in the imaging light path. (a) DMD array plane perpendicular to the lighting optical axis; (b) DMD array plane perpendicular to the imaging optical axis; (c) diagram of distance between Bi and Bj
    DMD mounted on optical platform with rotation angle of 45°
    Shaded model diagram of simulation system with Zemax non-sequence mode
    Distortion measurement template
    Distortion curves with different lighting sources. (a) Parallel source lighting; (b) ideal parallel source lighting; (c) non-parallel light source lighting (after point light source moving -1 mm along the axis); (d) non-parallel light source lighting (after point light source moving +1 mm along the axis)
    DMD pitch angle deviation, azimuth angle deviation, and roll angle deviation as functions of distortion in different FOVs
    Source simulation experimental system based on DMD. (a) Experimental light path; (b) collected image in distortion measurement experiment
    Distortion curve of experimental system
    Black and white grid images used to test contrast. (a) Input image of DMD; (b) acquired image of CMOS
    • Table 1. Main optical parameters of experimental system

      View table

      Table 1. Main optical parameters of experimental system

      ParameterValue
      Wavelength /nm617
      Effective focal length /mm201.8440
      Object distance /mm966.6993
      Image distance /mm252.2860
      F number15.0048
      Transverse magnification β-0.2630
      FOV /(°)1.0378
      Entrance pupil diameter /mm17.5104
      Total track /mm233.3776
    • Table 2. Table of feature points corresponding to three FOVs

      View table

      Table 2. Table of feature points corresponding to three FOVs

      FOV /(° )Feature point No.Distance from center point /pixel
      0.56,7,8,11,13,16,17,18160
      0.73,4,5,10,14,19,20,21320
      11,2,9,15,22,23480
    • Table 3. Distortion of system design, system simulation, and experiment

      View table

      Table 3. Distortion of system design, system simulation, and experiment

      FOV /(° )Imaging distortion /pixel
      System designSimulationExperiment
      0.50.01080.10610.0761
      0.70.02170.10480.1783
      10.03120.11650.4750
    Tools

    Get Citation

    Copy Citation Text

    Xueqi Chen, Aimin Jiang. Source Simulation Experimental System Based on Digital Micromirror Device[J]. Acta Optica Sinica, 2019, 39(10): 1011003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Apr. 8, 2019

    Accepted: Jun. 24, 2019

    Published Online: Oct. 9, 2019

    The Author Email: Chen Xueqi (chenxueqi@nao.cas.cn), Jiang Aimin (amjiang@bao.ac.cn)

    DOI:10.3788/AOS201939.1011003

    Topics