Laser & Optoelectronics Progress, Volume. 56, Issue 23, 231504(2019)

Binocular Stereo Vision Calibration Accuracy Evaluation Using Epipolar Constraint

Qingzhe Zhang* and Yong Wang
Author Affiliations
  • Key Laboratory of Road Construction & Equipment, Ministry of Education, Chang'an University, Xi'an, Shaanxi 710064, China
  • show less
    Figures & Tables(7)
    Epipolar constraint relationship
    Matching relationship between measured corner points of left image and its right epipolar line
    Real-time evaluation of camera calibration accuracy
    Calibration poses of 20 mm chessboard
    Calibration poses of 10 mm chessboard
    • Table 1. Results of five sets of calibration experiments

      View table

      Table 1. Results of five sets of calibration experiments

      Calibration sample(chess board size)Cameraf /pixel(c1, cr)k1k2p1p2
      1(10 mm)LeftRight(368.165,368.093)(373.519,372.718)(350.178,258.085)(353.876,265.347)0.05270.0392-0.0217-0.0173-0.00090.0004-0.00060.0040
      2(10 mm)LeftRight(371.442,371.330)(366.330,365.744)(346.833,255.428)(354.867,265.233)0.05390.03400.03010.0342-0.0010-0.0007-0.00090.0042
      3(20 mm)LeftRight(362.349,362.997)(368.832,369.370)(346.067,258.233)(353.880,266.318)0.02730.0312-0.0245-0.03830.00070.00110.00010.0010
      4(20 mm)LeftRight(370.017,370.576)(371.448,371.956)(349.697,259.817)(354.044,264.984)0.02880.0340-0.0363-0.04600.00040.00070.00010.0010
      5(20 mm)LeftRight(366.331,366.959)(372.603,373.075)(348.547,258.587)(353.470,265.876)0.02730.0374-0.0161-0.04040.00090.00090.00040.0011
    • Table 2. Comparison of measurement results by two methods of camera calibration accuracy evaluation

      View table

      Table 2. Comparison of measurement results by two methods of camera calibration accuracy evaluation

      Calibration sample(chess board size)Imageresidual /pixelMean absolute deviationof distance /pixelCamerabaseline /mmMeasurementerror /mm
      1(10 mm)0.29780.136960.260.26
      2(10 mm)0.26350.164361.111.11
      3(20 mm)0.18790.146860.420.42
      4(20 mm)0.20790.158460.910.91
      5(20 mm)0.21250.172161.211.21
    Tools

    Get Citation

    Copy Citation Text

    Qingzhe Zhang, Yong Wang. Binocular Stereo Vision Calibration Accuracy Evaluation Using Epipolar Constraint[J]. Laser & Optoelectronics Progress, 2019, 56(23): 231504

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Machine Vision

    Received: Apr. 11, 2019

    Accepted: Jun. 24, 2019

    Published Online: Nov. 27, 2019

    The Author Email: Zhang Qingzhe (zqzh@chd.edu.cn)

    DOI:10.3788/LOP56.231504

    Topics