Acta Optica Sinica, Volume. 39, Issue 11, 1128001(2019)

High-Precision Calibration Modeling of Point-Light-Source Turntable Based on Solar Vector

Ruijin Li1,2、**, Liming Zhang1、*, Weiwei Xu1, Xiaolong Si1, Jiawei Li1, Yunyou Hu1,2, Xianhua Wang1, and Jixiang Wang1
Author Affiliations
  • 1Key Laboratory of Optical Calibration and Characterization, Anhui Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Hefei, Anhui 230031, China
  • 2University of Science and Technology of China, Hefei, Anhui 230026, China
  • show less
    Figures & Tables(8)
    Composition of point light source turntable system. (a) Schematic of sun sensor; (b) coordinate system definition and structural diagram; (c) mirror reflectivity
    Fitting of calculated solar vector value and theoretical value with first group of data when μ0, ν0, and ω0 are 0, and α0 and β0 are initial values. (a) SU<mml:
    Fitting of calculated solar vector value and theoretical value with the second group of data when μ0, ν0, and ω0 are 0, and α0 and β0 are initial values. (a) SU
    Comparison of test results of elevation angle of turntable. (a) Angle measured by pitch encoder; (b) angle of pitch encoder calculated by calibrated model; (c) comparison of calculation and measurement values
    Comparison of azimuth measurement results of turntable. (a) Angle measured by azimuth encoder; (b) angle of azimuth encoder calculated by calibrated model; (c) comparison of calculation and measurement values
    Centroid pixels collected by camera at different sun positions and at different times. (a) Image centroid coordinates when sun observer is aligned with sun; (b) centroid coordinates of sun obtained by camera after calibration; (c) difference of pre-calibration and post-calibration pixels
    • Table 1. Partial test data of turntable when reflector optical axis points to sun

      View table

      Table 1. Partial test data of turntable when reflector optical axis points to sun

      Sun centroid /pixelx597.623598.108595.344595.612596.112595.264595.785595.980
      y525.468527.861524.679524.780524.854523.434529.098528.830
      Sun position /(°)Altitude50.46952.70453.21053.70453.96554.18749.20846.623
      Azimuth141.022147.820148.951150.703151.689152.562222.086227.280
      Encoder anglePitch216.460218.653219.173219.656219.964220.118215.150212.557
      value /(°)Azimuth279.436272.655271.506269.764268.775267.830198.259193.104
      Encoder originalPitch165.937165.937165.937165.937165.937165.937165.937165.937
      angle value /(°)Azimuth60.42560.42560.42560.42560.42560.42560.42560.425
    • Table 2. Partial test data used to the verification of turntable model

      View table

      Table 2. Partial test data used to the verification of turntable model

      Sun position /(°)Altitude45.05044.67044.31043.78043.09042.61042.11041.520
      Azimuth230.016230.644231.216232.047233.087233.786234.511235.332
      Measure encoderPitch46.12145.61645.30844.97944.34143.37542.86942.430
      value /(°)Azimuth229.680230.318230.977231.482232.449233.899234.580235.239
      Calculated encoderPitch46.09145.58945.28244.95244.31543.34942.84242.404
      value /(°)Azimuth229.649230.288230.944231.455232.417233.871234.552235.212
      Error calculatedPitch0.0300.0270.0260.0270.0260.0260.0270.026
      and measure /(°)Azimuth0.0310.0300.0330.0270.0320.0280.0280.027
    Tools

    Get Citation

    Copy Citation Text

    Ruijin Li, Liming Zhang, Weiwei Xu, Xiaolong Si, Jiawei Li, Yunyou Hu, Xianhua Wang, Jixiang Wang. High-Precision Calibration Modeling of Point-Light-Source Turntable Based on Solar Vector[J]. Acta Optica Sinica, 2019, 39(11): 1128001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Remote Sensing and Sensors

    Received: Jun. 11, 2019

    Accepted: Jul. 15, 2019

    Published Online: Nov. 6, 2019

    The Author Email: Li Ruijin (liruijinrona@163.com), Zhang Liming (lmzhang@aiofm.ac.cn)

    DOI:10.3788/AOS201939.1128001

    Topics