High Power Laser and Particle Beams, Volume. 33, Issue 5, 054001(2021)

Vibration of scanning magnet for space environment simulation and research infrastructure

Jiuwei Yu1...2, Yaqing Yang1,2, Minbang Lü1, Wenjun Cheng1, Yajun Zheng1, Xiaowei Xu1, Haijiao Lu1 and Yongxiang Pan1 |Show fewer author(s)
Author Affiliations
  • 1Institute of Modern Physics, Chinese Academy of Sciences, Lanzhou 730000, China
  • 2School of Nuclear Science and Technology, University of Chinese Academy of Sciences, Beijing 101400, China
  • show less
    References(10)

    [1] Jiang H P, Liu J L, Hao H F, et al. SESRI 300 MeV proton and heavy ion accelerator[J]. Journal of Physics: Conference Series, 1350, 012081(2019).

    [5] [5] Al Shehab M, Jdan A, Lakovakis E, et al. Vibration measurement & simulation of mag & girder in sesame[C]Mechanical Engineering Design of Synchrotron Radiation Equipment Instrumentation. 2018: 111113.

    [6] Trombik P, Fleischer P, Vassiliou M F. Vibration isolation measures due to the high sensitive linear accelerator at the Paul Scherrer Institute[J]. MATEC Web of Conferences, 24, 06006(2015).

    [7] [7] Turner J L, Adolphsen C, Bowden G B, et al. Vibration studies of the Stanfd Linear Accelerat[C]Proceedings Particle Accelerat Conference. 1995: 665667.

    [8] Liu Renhong, Zhang Junsong, Qu Huamin, et al. Vibration research of the AC dipole-girder system for CSNS/RCS[J]. Chinese Physics C, 38, 97-102(2014).

    [10] Bu Lingshan, Zhao Zhentang, Yin Lixin, et al. Vibration damping of magnet girder assembly of Shanghai synchrotron radiation facility's storage ring[J]. High Power Laser and Particle Beams, 20, 127-130(2008).

    [11] Le Breton R, Deleglise G, Allibe J, et al. Nanometer scale active ground motion isolator[J]. Sensors and Actuators A: Physical, 204, 97-106(2013).

    [12] [12] Riddone G, Schulte D, MainaudDur H, et al. Technical specification f the CLIC twobeam module[C]Proceedings of EPAC08. 2008: 607609.

    [13] Montag C. Active stabilization of mechanical quadrupole vibrations for linear colliders[J]. Nuclear Instruments and Methods in Physics Research Section A: Accelerators, Spectrometers, Detectors and Associated Equipment, 378, 369-375(1996).

    [14] [14] Fan Y, Tao F, Li Z, et al. Vibrational stability of a cryocooled double crystal monochromat at SSRF[C]Mechanical Engineering Design of Synchrotron Radiation Equipment Instrumentation. Paris: JACoW Publishing, 2018: 220222.

    Tools

    Get Citation

    Copy Citation Text

    Jiuwei Yu, Yaqing Yang, Minbang Lü, Wenjun Cheng, Yajun Zheng, Xiaowei Xu, Haijiao Lu, Yongxiang Pan. Vibration of scanning magnet for space environment simulation and research infrastructure[J]. High Power Laser and Particle Beams, 2021, 33(5): 054001

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Particle Beams and Accelerator Technology

    Received: Nov. 16, 2020

    Accepted: --

    Published Online: Jun. 24, 2021

    The Author Email:

    DOI:10.11884/HPLPB202133.200311

    Topics