Acta Optica Sinica, Volume. 41, Issue 5, 0522002(2021)

Indirect Imaging Method of Ritchey-Chretien Optical System with Large Field of View

Hanqing Zheng, Qingfeng Cui*, Yang Hu, Lin Sun, Yu Guo, and Xudong Gao
Author Affiliations
  • School of Opto-Electronic Engineering, Changchun University of Science and Technology, Changchun, Jilin 130022, China
  • show less
    Figures & Tables(11)
    Flowchart of indirect imaging method
    Structure of optical system
    Point diagram of R-C system at different angles. (a) 0°; (b) 0.225°; (c) 0.315°; (d) 0.450°
    Fitting results of Zernike polynomials
    Wavefront comparison of R-C systems at different fields of view. (a) 0.12°; (b) 0.22°; (c) 0.34°; (d) 0.45°
    PSF comparison of R-C system in different fields of view. (a) 0.15°; (b) 0.30°; (c) 0.45°
    Comparison of results before and after restoration. (a) Image of before restoration; (b) image of after restoration; (c) local enlarged view of Fig. (a); (d) local enlarged view of Fig. (b)
    Comparison of results before and after restoration of resolution plate. (a) Local enlarged view of Fig. (c); (b) local enlarged view of Fig. (b); (c) image of before restoration; (d) image of after restoration
    MTF comparison curves before and after restoration. (a) Before restoration; (b) after restoration
    • Table 1. Correspondence between Zernike polynomials and aberrations

      View table

      Table 1. Correspondence between Zernike polynomials and aberrations

      TermZernike polynomialName
      Z001Displacement
      Z11Rcos θX-tilt
      Z1-1Rsin θY-tilt
      Z202R2-1Defocus
      Z22R2cos 2θ0° astigmatism
      Z2-2R2sin 2θ45° astigmatism
      Z31(3R3-2R)cos θX-coma
      Z3-1(3R3-2R)sin θY-coma
      Z406R4-6R2+1Spherical aberration
    • Table 2. Index parameters of system

      View table

      Table 2. Index parameters of system

      ParameterContent
      F-number4
      Focal length /mm1300
      Field of view /(°)0.9
      Wavelength /nm900--1700
    Tools

    Get Citation

    Copy Citation Text

    Hanqing Zheng, Qingfeng Cui, Yang Hu, Lin Sun, Yu Guo, Xudong Gao. Indirect Imaging Method of Ritchey-Chretien Optical System with Large Field of View[J]. Acta Optica Sinica, 2021, 41(5): 0522002

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jul. 21, 2020

    Accepted: Oct. 16, 2020

    Published Online: Apr. 7, 2021

    The Author Email: Cui Qingfeng (qf_cui@163.com)

    DOI:10.3788/AOS202141.0522002

    Topics