Laser & Optoelectronics Progress, Volume. 56, Issue 22, 221101(2019)

Calibration Method for Line-Structured Light

Ruifeng Zhang, Ziyun Shu*, and Ganglei Nan
Author Affiliations
  • School of Microelectronics, Tianjin University, Tianjin 300072, China
  • show less
    Figures & Tables(10)
    Camera perspective projection model
    Diagram of line-structured light sensor
    Flow chart of calibration for line-structured light
    Images taken by light plane calibration
    Picture of engine cylinder head
    Three-dimensional point clouds after encapsulation. (a) Top view; (b) front view
    • Table 1. Calibration results of two calibration methods

      View table

      Table 1. Calibration results of two calibration methods

      Method of calibrationNumber of feature pointsEquation of light plane
      Invariance of cross-ratio80.999438X-0.0333133Y-0.00363374Z+68.6157=0
      Our methodAll feature points on the light stripe0.999414X-0.0340966Y+0.00295146Z+65.1016=0
    • Table 2. Evaluation results of calibration results of two calibration methods

      View table

      Table 2. Evaluation results of calibration results of two calibration methods

      Method ofcalibrationNumber offeature pointsSum of thedistances /mm
      Invariance ofcross-ratioAll feature points32.74879
      Out methodAll feature points31.73931
    • Table 3. Measurement results of cylinder head based on proposed method

      View table

      Table 3. Measurement results of cylinder head based on proposed method

      GascavityX directionY directionZ direction
      Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%
      A1261.12261.210.090.03447.3047.210.090.190////
      B1261.12261.090.030.0110.000.100.10/////
      C1274.82274.900.080.029131.65131.690.040.03052.3052.640.340.650
      A2130.56130.500.060.04547.3047.250.050.105////
      B2130.56130.630.070.0530.000.090.09/////
      C2144.26144.350.090.062131.65131.600.050.03752.3052.560.260.497
      A300.080.08/47.3047.400.100.211////
      B3000/00.090.09/////
      C313.7013.750.050.360131.65131.700.050.03752.3052.650.350.669
      A4130.56130.620.060.04547.3047.400.100.211////
      B4130.56130.480.080.0610.000.060.06/////
      C4116.86116.960.100.085131.65131.600.050.03752.3052.450.150.287
    • Table 4. Measurement results of cylinder head obtained by cross ratio invariance based calibration method

      View table

      Table 4. Measurement results of cylinder head obtained by cross ratio invariance based calibration method

      GascavityX directionY directionZ direction
      Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%Stand-ard /mmMeas-ured /mmAbsoluteerror /mmRelativeerror /%
      A1261.12261.210.090.03447.3047.210.090.190////
      B1261.12261.090.030.0110.000.110.11/////
      C1274.82274.900.080.029131.65131.970.320.24352.3052.990.691.319
      A2130.56131.200.640.49047.3047.160.140.295////
      B2130.56130.160.400.3060.000.380.38/////
      C2144.26144.880.620.429131.65131.970.320.24352.3053.210.911.739
      A30-0.080.08/47.3047.450.150.317////
      B3000/000/////
      C313.7013.750.050.360131.65131.970.320.24352.3052.640.340.650
      A4130.56130.330.230.17647.3046.930.370.782////
      B4130.56130.380.180.1370.000.150.15/////
      C4116.86117.220.360.308131.65131.970.320.24352.3052.460.160.305
    Tools

    Get Citation

    Copy Citation Text

    Ruifeng Zhang, Ziyun Shu, Ganglei Nan. Calibration Method for Line-Structured Light[J]. Laser & Optoelectronics Progress, 2019, 56(22): 221101

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Imaging Systems

    Received: Mar. 14, 2019

    Accepted: May. 13, 2019

    Published Online: Nov. 2, 2019

    The Author Email: Shu Ziyun (szy826@tju.edu.cn)

    DOI:10.3788/LOP56.221101

    Topics