Chinese Journal of Quantum Electronics, Volume. 20, Issue 3, 292(2003)
High Sensitivity Continuous-wave Cavity Ring-Down Infrared Spectroscopy Based on a Rapidly Swept Cavity
[1] [1] Berden G, Peeters R, Meijer G. Cavity ring-down spectroscopy: experimental schemes and applications [J]. Int.Rev. Phys. Chem., 2000, 19(4): 565-607
[2] [2] Newman S M, Lane I C, Orr-Ewing AJ et al. Integrated absorption intensity and Einstein coefficients for the O2a1△g - X3 ∑-g (0,0) transition: a comparison of cavity ringdown and high resolution Fourier transform spectroscopy with a long-path absorption cell [J]. J. Chem. Phys., 1999, 110(22): 10749-10757
[3] [3] Ball S M, Povey I M, Norton E G et al. Boardband cavity ringdown spectroscopy of the NO3 radical [J]. Chem.Phys. Lett., 2001, 342(1-2): 113-120
[4] [4] Hahn Jae Won, Yoo Yong Shim, Lee Jae Yong et al. Cavity ringdown spectroscopy with a continuous-wave Laser:calculation of coupling efficiency and a new spectrometer design [J]. Appl. Opt-LP, 1999, 38(9): 1859-1866
[5] [5] He Yabai, Orr Brian J. Optical heterodyne signal generation and detection in cavity ringdown spectroscopy based on a rapid swept cavity [J]. Chem. Phys. Lett., 2001, 335(3-4): 215-220
[6] [6] He Yabai, Orr Brian J. Ringdown and cavity-enhanced absorption spectroscopy using a continuous-wave tunable diode laser and a rapidly swept optical cavity [J]. Chem. Phys. Lett. 2000, 319(1-2): 131-137
[7] [7] Richard E, von Gert H, Giel B et al. Phase shift cavity ring down absorption spectroscopy [J]. Chem. Phys. Lett., 1996, 262 (1-2): 105-109
[8] [8] Romanini D, Kachanov A A, Sadeghi N et al. CW cavity ring down spectroscopy [J]. Chem. Phys. Lett., 1997,264(3-4): 316-322
[9] [9] Romanini D, Kachanov A A, Stoeckel F. Diode laser cavity ring down spectroscopy [J]. Chem. Phys. Lett., 1997,270(5-6): 538-545
[10] [10] Romanini D, Kachanov A A, Stoeckel F. Cavity ringdown spectroscopy: broad band absolute absorption measurements [J]. Chem. Phys. Lett., 1997, 270(5-6): 546-550
[11] [11] O'Keefe Anthony, Scherer James J, Paul Joshua B. CW integrated cavity output spectroscopy [J]. Chem. Phys.Lett., 1999, 307(5-6): 343-349
[12] [12] He Y, Hippler M, Quack M. High-resolution cavity ring-down absorption spectroscopy of nitrous oxide and chloroform using a near-infrared cw diode laser [J]. Chem. Phys. Lett., 1998, 289 (5-6): 527-534
[13] [13] Levenson M D, Paldus B A, Spence T G et al. Optical heterodyne detection in cavity ring-down spectroscopy [J]. Chem. Phys. Lett., 1998, 290(4-6): 335-340
[14] [14] Levenson M D, Paldus B A, Spence T G et al. Frequency-switched heterodyne cavity ringdown spectroscopy [J].Opt. Lett., 2000, 25(12): 920-922
[15] [15] Ye J, Hall J L. Cavity ringdown heterodyne spectroscopy: high sensitivity with microwatt light power [J]. Phys.Rev. A, 2000, 61(6): 061802
Get Citation
Copy Citation Text
[in Chinese], [in Chinese]. High Sensitivity Continuous-wave Cavity Ring-Down Infrared Spectroscopy Based on a Rapidly Swept Cavity[J]. Chinese Journal of Quantum Electronics, 2003, 20(3): 292