Journal of Applied Optics, Volume. 40, Issue 3, 411(2019)
Research on distribution of aperture position error in multi-beam coherent imaging and its impact on image quality
[1] [1] HOLMES R B, MA S, BHOWMIK A, et al. Analysis and simulation of a synthetic-aperture technique for imaging through a turbulent medium[J]. Journal of the Optical Society of America A, 1996, 13(2): 351-364.
[2] [2] YU Shuhai, WANG Jianli, DONG Lei, et al. Application informal phase closure about image reconstruction algorithm based on fourier telescopy[J]. Acta Photonica Sinica, 2015, 44(5):0511002-1-0511002-7.
[4] [4] LUO Xiujuan, ZHANG Yu, SUN Xin, et al. Energy design of fourier telescope system in the atmospheric environment[J]. Acta Optica Sinica, 2013, 33(8):0801004-1-8.
[5] [5] ZENG Zhihong, LUO Xiujuan, WANG Baofeng, et al. Laboratory simulation of atmosphere turbulence for fourier telescopy[J]. Acta Photonica Sinica, 2014, 43(6): 214-220.
[6] [6] JAMES S, BRETT S, LAURENCE C, et al. Simulation of a Fourier telescopy imaging system for objects in low earth orbit[J]. SPIE, 2006, 6307(2): 630701-1-11.
[7] [7] STEPHEN D F, DAVID G V, VICTOR L, et al. Geo light imaging national testbed (GLINT) past, present, and future[J]. SPIE, 1999, 0277(2): 1-10.
[8] [8] LUO Xiujuan, ZHANG Yu, GAO Cunxiao, et al. Performance analysis of laser transmitting system for Fourier telescope[J]. Acta Optica Sinica, 2015, 35(3):0314001-1-10.
[9] [9] KANG Meiling, YANG Chunping, Wu Jian. Reconstruction of uncompleted frequency spectrum images based on Fourier telescopy [J]. SPIE, 2008, 7495(4): 74954G-1-10.
[10] [10] ZHANG Wenxi, XIANG Libin, KONG Xinxin, et al. Resolution of coherent field imaging technique[J]. Acta Physica Sinica, 2013, 62(16): 169-174.
[11] [11] HOLMES R B. Aperture-synthesis techniques that use very-low-illumination[J]. SPIE, 2008, 2566(3): 177-185.
[12] [12] CHENG Zhiyuan, MA Caiwen, LUO Xiujuan, et al. Improving coherent field imaging quality by suppressing the influence of transmitting aperture spacing error[J]. Acta Physica Sinica, 2015, 64(12): 124203-1-8.
[14] [14] ZHANG Yu, LUO Xiujuan, XIA Aili, et al. Image quality evaluation and analysis in fourier telescopy for laboratory demonstration[J]. Acta Photonica Sinica, 2014, 43(3): 160-165.
[15] [15] ZHANG Yu. Research on influnence factors of imaging quality of fourier telescopy system [D]. Beijing: Chinese Academy of Science, 2015.
Get Citation
Copy Citation Text
ZHANG Yu, LUO Xiujuan, LIU Hui, CHEN Minglai, CHENG Zhiyuan, LAN Fuyang. Research on distribution of aperture position error in multi-beam coherent imaging and its impact on image quality[J]. Journal of Applied Optics, 2019, 40(3): 411
Category:
Received: Aug. 15, 2018
Accepted: --
Published Online: Jun. 10, 2019
The Author Email: