Optics and Precision Engineering, Volume. 25, Issue 1, 217(2017)

Smear correction of asynchronous binning high frame rate CCD camera

LIU Lu... LUO Tong-ding, LI Bin-kang, YANG Shao-hua and YAN Ming |Show fewer author(s)
Author Affiliations
  • [in Chinese]
  • show less
    References(15)

    [1] [1] LI B K, YANG SH H, GUO M A, et al.. Design of a very high frame rate camera based on an asynchronous CCD driving method [J]. Chinese Physics C, 2011, 35(6): 572-575.

    [2] [2] KAZUYA Y. The Basis of CCD/CMOS Image Sensors and Applications [M]. CHEN R T, PENG M ZH.TRANSLATION. Beijing: Science Press, 2006.(in Chinese)

    [4] [4] KAO W CH, HONG C M, LIN S Y. Automatic sensor and mechanical shutter calibration for digital still cameras[J].IEEE Transactions on Consumer Electronics, 2005, 51(4): 1060-1066.

    [5] [5] GAO J W, YAO R, SUN J Q, et al.. Smear removal algorithm for frame transfer CCD sensors [J]. Chinese Journal of Stereology and Image Analysis, 2010, 15(4): 394-398.(in Chinese)

    [7] [7] CHEN J W, CAO K Q, SUN D X, et al.. Driving techniques for high-frame-rate frame transfer CCDs with low smear [J]. Infrared and Laser Engineering, 2016, 45(1): 0123001.(in Chinese)

    [9] [9] GAO J W, ZHANG ZH, YAO R, et al.. A robust smear removal method for inter-frame charge-coupled devices star images [C].2011 7th International Conference on Natural Computation, 2011: 1805-1808.

    [10] [10] GAO J W, ZHANG ZH, YAO R, et al.. Smear radiometric correction algorithm in star images based on kernel density estimation [J]. SPIE, 2011, 8194: 819421.

    [11] [11] FENG W W, CHEN L G. Smear correction of frame transfer CCD camera based on the integrating sphere [J].Optik, 2013, 124: 1805-1807.

    [12] [12] LUO T D, LI B K, GUO M A, et al.. Smear correction of high frame rate camera based on asynchronous CCD drive [J].High Power Laser and Particle Beams, 2013, 25(7): 1680-1684.

    [13] [13] CHEN Y H, ZHOU W, SHEN W M. The research of smearing elimination of remote sensing images [J]. SPIE, 2007, 6833: 68331W.

    [14] [14] HAN C Q, LIU ZH B. Disposal of smearing in scientific grade frame-transfer type CCD camera [J].Science Technology and Engineering, 2009, 9(15): 4336-4338.(in Chinese)

    CLP Journals

    [1] Zhang Mengjiao, Cai Yi, Ye Liang, Chen Yuanjin, Xu Chunye, Wang Lingxue. Electronic shutter for frame-transfer EMCCD using anti-blooming channel to bleed off charges[J]. Infrared and Laser Engineering, 2018, 47(6): 620001

    Tools

    Get Citation

    Copy Citation Text

    LIU Lu, LUO Tong-ding, LI Bin-kang, YANG Shao-hua, YAN Ming. Smear correction of asynchronous binning high frame rate CCD camera[J]. Optics and Precision Engineering, 2017, 25(1): 217

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Jun. 15, 2016

    Accepted: --

    Published Online: Mar. 10, 2017

    The Author Email:

    DOI:10.3788/ope.20172501.0217

    Topics