Laser & Optoelectronics Progress, Volume. 59, Issue 13, 1312003(2022)

Accurate Local Homography-Based Projector Calibration Method

Lijun Sun1,2,3, Dandan Zhang1,2,3, Tianfei Chen1,2,3、*, Zhiyuan Huang1,2,3, and Shi Li1,2,3
Author Affiliations
  • 1Key Laboratory of Grain Information Processing and Control of Ministry of Education, Henan University of Technology, Zhengzhou 450001, Henan , China
  • 2Zhengzhou Key Laboratory of Machine Perception and Intelligent System, Henan University of Technology, Zhengzhou 450001, Henan , China
  • 3College of Information Science and Engineering, Henan University of Technology, Zhengzhou 450001, Henan , China
  • show less
    Figures & Tables(12)
    Ideal pinhole model
    Perspective projection transformation
    Concentric circles in the camera image plane
    Flow chart of double four step phase shift
    Projector coordinate mapping process
    Projector coordinates calculation process
    Experimental setup. (a) Projector calibration system; (b) calibration target
    Projector calibration accuracy at different N values.(a) N=2; (b) N=12; (c) N=13; (d) N=21; (e) N=34; (f) N=48; (g) calibration accuracy trend chart
    Re-projection error of different calibration methods. (a) P2P mapping method; (b) method in Ref. [16]; (c) method in Ref. [20]; (d) proposed method
    • Table 1. The standard deviation of projector calibration

      View table

      Table 1. The standard deviation of projector calibration

      MethodEstd uEstd v
      P2P mapping method1.330780.99727
      After center deviation correction1.229370.89716
      After phase error compensation0.848130.70704
      Proposed mapping method0.719850.53907
    • Table 2. Calibration results of different methods

      View table

      Table 2. Calibration results of different methods

      Methodfufvup0vp0k1k2p1p2
      P2P mapping method1416.501037.57388.54429.12-0.42861.2574-0.0377-0.0031
      Method in Ref.[161375.471010.02390.98425.89-0.31850.9048-0.0295-0.0024
      Method in Ref.[201356.29995.08393.75427.27-0.29620.7666-0.0304-0.0025
      Proposed method1351.08991.03398.31424.24-0.30770.7914-0.0301-0.0020
    • Table 3. Calibration error of different methods

      View table

      Table 3. Calibration error of different methods

      MethodEmaxuEmaxvEmean uEmean vEstd uEstd v
      P2P mapping method4.584913.322721.050360.791671.330780.99727
      Method in Ref.[162.944802.200790.680680.559340.848130.70704
      Method in Ref.[201.802481.891240.445930.403780.561400.50607
      Proposed method1.256291.398910.321770.294910.401920.37253
    Tools

    Get Citation

    Copy Citation Text

    Lijun Sun, Dandan Zhang, Tianfei Chen, Zhiyuan Huang, Shi Li. Accurate Local Homography-Based Projector Calibration Method[J]. Laser & Optoelectronics Progress, 2022, 59(13): 1312003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Aug. 9, 2021

    Accepted: Aug. 23, 2021

    Published Online: Jun. 9, 2022

    The Author Email: Chen Tianfei (chen_tianfei@163.com)

    DOI:10.3788/LOP202259.1312003

    Topics