Optics and Precision Engineering, Volume. 32, Issue 15, 2363(2024)

Aperture stop diffraction effect of solar irradiance measurement

Jieling YU1...2, Hang DONG1,2, Xiaolong YI1, Yuchen LIN1,2, Silong WANG3, Qingxiang MIAO4, Rui SUN5, Zhanpeng GAO6, Wei FANG1 and Xin YE1,* |Show fewer author(s)
Author Affiliations
  • 1Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, Changchun30033, China
  • 2University of the Chinese Academy of Sciences, Beijing100049, China
  • 3Lunar Exploration and Space Engineering Center, Beijing100048, China
  • 4Optoelectronic Information Science and Engineering, Changchun University of Science and Technology, Changchun130013, China
  • 5School of Electrical and Information Engineering, Jilin Engineering and Technology Normal University, Changchun130062, China
  • 6School of Materials Science and Chemical Engineering, Harbin Engineering University, Harbin15000, China
  • show less
    References(17)

    [1] S K SOLANKI, N A KRIVOVA, J D HAIGH. Solar irradiance variability and climate. Annual Review of Astronomy and Astrophysics, 51, 311-351(2013).

    [2] G THUILLIER, P ZHU, M SNOW et al. Characteristics of solar-irradiance spectra from measurements, modeling, and theoretical approach. Light: Science & Applications, 11, 79(2022).

    [3] G L STEPHENS, J LI, M WILD et al. An update on Earth’s energy balance in light of the latest global observations. Nature Geoscience, 5, 691-696(2012).

    [4] C FRÖHLICH. Total solar irradiance observations. Surveys in Geophysics, 33, 453-473(2012).

    [5] B Q SONG, X YE, W FINSTERLE et al. The Fengyun-3E/joint total solar irradiance absolute radiometer: instrument design, characterization, and calibration. Solar Physics, 296, 52(2021).

    [6] [6] 郭旭, 胡春晖, 颜昌翔, 等. 基于蒙特卡罗法的星载太阳辐照度光谱仪对日指向误差分析[J]. 光学 精密工程, 2021, 29(3): 474-483. doi: 10.37188/ope.20212903.0474GUOX, HUCH H, YANCH X, et al. Analysis of Sun pointing error of spaceborne solar spectroradiom-eter based on Monte Carlo method[J]. Opt. Precision Eng., 2021, 29(3): 474-483.(in Chinese). doi: 10.37188/ope.20212903.0474

    [7] H R WANG, Y P WANG, X YE et al. Instrument description: the total solar irradiance monitor on the FY-3C satellite, an instrument with a pointing system. Solar Physics, 292, 8(2016).

    [8] [8] 高鑫, 王凯, 方伟. 太阳辐照度绝对辐射计吸收腔结构优化[J]. 光学 精密工程, 2018, 26(3): 624-631. doi: 10.3788/ope.20182603.0624GAOX, WANGK, FANGW. Optimization on the structure of the absorption cavity of solar irradiance absolute radiometer[J]. Opt. Precision Eng., 2018, 26(3): 624-631.(in Chinese). doi: 10.3788/ope.20182603.0624

    [9] X YE, X L YI, C LIN et al. Instrument development: Chinese radiometric benchmark of reflected solar band based on space cryogenic absolute radiometer. Remote Sensing, 12, 2856(2020).

    [10] X TANG, Y Z XIA, W FANG et al. International comparison of the SIAR measurement and the WRR standard. Optoelectronics Letters, 15, 147-150(2019).

    [11] [11] 衣小龙, 杨振岭, 叶新, 等. 低温辐射计斜底腔吸收比测量[J]. 光学 精密工程, 2015, 23(10): 2733-2739. doi: 10.3788/ope.20152310.2733YIX L, YANGZH L, YEX, et al. Absorptance measurement for sloping bottom cavity of cryogenic radiometer[J]. Opt. Precision Eng., 2015, 23(10): 2733-2739.(in Chinese). doi: 10.3788/ope.20152310.2733

    [12] [12] 刘国栋. 太阳辐照绝对辐射计衍射效应分析与修正[D]. 长春: 中国科学院长春光学精密机械与物理研究所, 2017.LIUG D. Analysis and Correction of Diffraction Effect of Solar Irradiation Absolute Radiometer[D].Changchun: Changchun Institute of Optics, Fine Mechanics and Physics, Chinese Academy of Sciences, 2017. (in Chinese)

    [13] W S C CHANG. Principles of Optics for Engineers: Diffraction and Modal Analysis.

    [14] D M HARBER, K F HEUERMAN, G A KOPP et al. Aperture edge scatter calibration of the cavity radiometers for the spaceflight Total Irradiance Monitor, 6296(2006).

    [15] [15] 常松涛, 夏豪杰. 时间延迟积分荧光显微成像平场校正技术[J]. 光学 精密工程, 2022, 30(5): 527-535. doi: 10.37188/OPE.20223005.0527CHANGS T, XIAH J. Flat field correction technique for time delay integration fluorescence microscopy imaging[J]. Opt. Precision Eng., 2022, 30(5): 527-535.(in Chinese). doi: 10.37188/OPE.20223005.0527

    [16] [16] 郑翔远, 叶新, 罗志涛, 等. 高精度辐射热流计的不确定度分析与评价[J]. 中国光学, 2022, 15(4): 780-788. doi: 10.37188/co.2022-0023ZHENGX Y, YEX, LUOZH T, et al. Uncertainty analysis and evaluation of a high-precision radiative heat-flux meter[J]. Chinese Optics, 2022, 15(4): 780-788.(in Chinese). doi: 10.37188/co.2022-0023

    [17] [17] 夏桂锁, 廖城, 伏燕军. 平行双关节坐标测量机的标定及不确定度评价[J]. 光学 精密工程, 2014, 22(5): 1227-1234. doi: 10.3788/ope.20142205.1227XIAG S, LIAOCH, FUY J. Calibration and uncertainty evaluation of double parallel-joint coordinate measuring machine[J]. Opt. Precision Eng., 2014, 22(5): 1227-1234.(in Chinese). doi: 10.3788/ope.20142205.1227

    Tools

    Get Citation

    Copy Citation Text

    Jieling YU, Hang DONG, Xiaolong YI, Yuchen LIN, Silong WANG, Qingxiang MIAO, Rui SUN, Zhanpeng GAO, Wei FANG, Xin YE. Aperture stop diffraction effect of solar irradiance measurement[J]. Optics and Precision Engineering, 2024, 32(15): 2363

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Mar. 26, 2024

    Accepted: --

    Published Online: Sep. 27, 2024

    The Author Email: YE Xin (yexin@ciomp.ac.cn)

    DOI:10.37188/OPE.20243215.2363

    Topics