Chinese Optics Letters, Volume. 15, Issue 2, 021402(2017)

Intra-cavity round-trip loss measurement of all-solid-state single-frequency laser by introducing extra nonlinear loss

Yongrui Guo1, Huadong Lu1,2、*, Qiwei Yin1, and Jing Su1,2
Author Affiliations
  • 1State Key Laboratory of Quantum Optics and Quantum Optics Devices, Institute of Opto-Electronics, Shanxi University, Taiyuan 030006, China
  • 2Collaborative Innovation Center of Extreme Optics, Shanxi University, Taiyuan 030006, China
  • show less
    Figures & Tables(8)
    Schematic diagram of the experimental setup. S1, S2: beam splitter; f1, f2: coupling lens; f3: lens; PBS: polarization beam splitter; PD: photodiode detector.
    Long-term power stabilities of 1064 nm laser and 532 nm laser for 5 h.
    Longitudinal-mode structure of the laser by scanning the confocal Fabry–Perot cavity.
    Measured result of the beam quality.
    Output powers of 1064 and 532 nm versus the temperature of the LBO crystal and the relevant temperature values for measurement of the intra-cavity round-trip loss.
    • Table 1. Output Powers of 1064 and 532  nm and the Nonlinear Conversion Factors with the Temperature of the LBO Crystal at (A), (B), (C), (D), (E), and (F)

      View table
      View in Article

      Table 1. Output Powers of 1064 and 532  nm and the Nonlinear Conversion Factors with the Temperature of the LBO Crystal at (A), (B), (C), (D), (E), and (F)

      NumberT/°CΔT/°CPf/WPsh/Wη/(m2/W)
      A149.0022.321.2396.5×1011
      B149.40.422.401.1826.166×1011
      C149.80.822.641.0235.662×1011
      D150.21.222,940.7893.957×1011
      E150.61.623.270.5272.582×1011
      F151.02.023.530.2871.379×1011
    • Table 2. Parameters of the Experimental Laser

      View table
      View in Article

      Table 2. Parameters of the Experimental Laser

      t19%
      I08.30827×106W/m2
      Pin74 W
      l18 mm
      deff1.16×1012V/m
      ε08.85×1012F/m
      c3×108m/s
      n1.56
      λf1064 nm
      λsh532 nm
      ω1390 μm
      ω284 μm
    • Table 3. Calculated Results for the Intra-Cavity Round-Trip Loss and the Pump Factor Value, Average Value, and the Standard Deviation Value

      View table
      View in Article

      Table 3. Calculated Results for the Intra-Cavity Round-Trip Loss and the Pump Factor Value, Average Value, and the Standard Deviation Value

      EqsL (%)K (%. W1)
      (A,B)6.857.47
      (A,C)4.296.75
      (A,D)3.996.67
      (A,E)4.96.92
      (A,F)4.976.94
      (B,C)3.496.53
      (B,D)3.486.57
      (B,E)4.746.88
      (B,F)4.866.91
      (C,D)3.656.58
      (C,E)5.187
      (C,F)5.197
      (D,E)6.667.42
      (D,F)5.197.01
      (E,F)5.217.01
      Average value4.846.91
      Standard deviation0.260.07
    Tools

    Get Citation

    Copy Citation Text

    Yongrui Guo, Huadong Lu, Qiwei Yin, Jing Su. Intra-cavity round-trip loss measurement of all-solid-state single-frequency laser by introducing extra nonlinear loss[J]. Chinese Optics Letters, 2017, 15(2): 021402

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Lasers and Laser Optics

    Received: Sep. 24, 2016

    Accepted: Dec. 6, 2016

    Published Online: Jul. 26, 2018

    The Author Email: Huadong Lu (luhuadong@sxu.edu.cn)

    DOI:10.3788/COL201715.021402

    Topics