Acta Optica Sinica, Volume. 38, Issue 10, 1022004(2018)

Multi-Degree-of-Freedom Uniformity Correction Method of Illumination System in Lithography Machine

Weilin Cheng1,2、*, Fang Zhang1, Dongliang Lin1,2, Aijun Zeng1,2, Baoxi Yang1,2, and Huijie Huang1,2、*
Author Affiliations
  • 1 Laboratory of Information Optics and Opto-Electronic Technology, Shanghai Institute of Optics and Fine Mechanics, Chinese Academy of Sciences, Shanghai 201800, China
  • 2 University of Chinese Academy of Sciences, Beijing 100049, China
  • show less
    Figures & Tables(12)
    Schematic of illumination system comprising multi-degree-of-freedom integrated uniformity correction unit. (a) Schematic of illumination system in lithography machine; (b) schematic of multi-degree-of-freedom uniformity correction
    Relationship between light intensity at any point of reticle plane and that in pupil region at corrected plane
    Schematic of interaction between correction fingers with change in xy plane and pupil region. (a) Correction fingers moving along y direction; (b) adjusting correction finger width
    Schematic of interaction between correction fingers with different defocusing distances and pupil region. (a) Interaction of correction fingers and pupil in yz plane; (b) interaction of correction fingers and pupil in axonometric projection; (c) interaction of correction fingers and pupil in xy plane
    Computational model for describing influence of correction finger defocusing distance on shaded pupil region
    Simulation model for 65 nm node illumination system in lithography machine
    Layout of fingers
    Relationship between correction finger width and corresponding integrated illumination uniformity after correction
    Correction finger positions and integrated uniformity curve obtained after correction by finger movement alone y direction. (a) Correction finger positions and (b) corrected integrated uniformity curves under conventional illumination mode with σ=0.15; (c) correction finger positions and (d) corrected integrated uniformity curves under annular illumination mode with σin=0.16 and σout=0.36
    Correction finger positions and integrated uniformity curves when illumination parameter is most of coherence factor, and correction finger width, distance from illumination light and defocusing distance are kept constant. (a) Correction finger positions and (b) corrected integrated uniformity curves under conventional illumination mode with σ=0.93; (c) correction finger positions and (d) corrected integrated uniformity curves under annular illumination mode with σin=0.76 and σout=0.96
    Correction finger positions when illumination parameter is most of coherence factor and integrated uniformity curves obtained after correction by adjusting correction finger defocusing distance, and correction finger width and distance from illumination light are kept constant. (a) Correction finger positions and (b) corrected integrated uniformity curves under conventional illumination mode with σ=0.93; (c) correction finger positions and (d) corrected integrated uniformity curves under annular
    • Table 1. Simulation results by multi-degree-of-freedom uniformity correction method

      View table

      Table 1. Simulation results by multi-degree-of-freedom uniformity correction method

      ConditionΔz /mmUcorrectedSatisfaction evaluation
      Conventional illuminationσ=0.15250.29%Satisfaction
      σ=0.93250.63%Dissatisfaction
      4.60.293%Satisfaction
      Annular illuminationσin=0.16σout=0.36250.262%Satisfaction
      σin=0.76σout=0.96250.54%Dissatisfaction
      130.27%Satisfaction
    Tools

    Get Citation

    Copy Citation Text

    Weilin Cheng, Fang Zhang, Dongliang Lin, Aijun Zeng, Baoxi Yang, Huijie Huang. Multi-Degree-of-Freedom Uniformity Correction Method of Illumination System in Lithography Machine[J]. Acta Optica Sinica, 2018, 38(10): 1022004

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Jan. 31, 2018

    Accepted: May. 21, 2018

    Published Online: May. 9, 2019

    The Author Email:

    DOI:10.3788/AOS201838.1022004

    Topics