Infrared and Laser Engineering, Volume. 53, Issue 8, 20240189(2024)

Method of stray light suppression for annular folded aperture imaging system

Yuanming ZHAO1, Bo ZHANG2、*, Chengran ZHANG2, Yafeng XIE1, Qun NIU1, and Jinli TANG1
Author Affiliations
  • 1The 27th Research Institute of CETC, Zhengzhou 450047, China
  • 2School of Opto-electronic Engineering, Changchun University of Science and Technology, Changchun 130022, China
  • show less
    Figures & Tables(15)
    Paraxial folded manner of annular aperture imaging system. (a) Refraction structure; (b) Paraxial annular aperture of reflective structure
    Light collection of different reflection times for annular folded aperture imaging system
    Layout of the annular folded aperture imaging system
    MTF curve of the annular folded aperture imaging system
    Design structure of the lens hood
    The stray light of annular aperture imaging system
    The relationship between lens hood length and field of view
    PST curve without the stray light suppression hood
    Layout of stray light for the annular aperture imaging system without the light shield
    The spot illumination before optimizing stray light
    Layout of stray light for the annular aperture imaging system with the light shield
    The spot illumination after optimizing stray light
    Comparison of the PST curves before and after stray light optimization
    • Table 1. Design index of annular aperture imaging system

      View table
      View in Article

      Table 1. Design index of annular aperture imaging system

      ParameterValue
      Effective focal length/mm60
      Effective F#1.4
      Wavelength/μm7.7-10
      Pixel size12 μm×12 μm
      Detector size7.68 mm×7.68 mm
      Field of view (2ω)/(°)9.8
      Lens thickness/mm≤19
    • Table 2. The PST values of the key angles

      View table
      View in Article

      Table 2. The PST values of the key angles

      Angle/(°)Infrared PST
      Before optimizationAfter optimization
      90.0529161.20424E-04
      100.0343193.40796E-04
      130.0390333.15205E-05
      210.0009628.21207E-06
      300.0086871.97150E-06
      330.0071221.30376E-06
      340.0058421.59683E-06
      350.0040578.79987E-07
      490.0040011.60951E-07
    Tools

    Get Citation

    Copy Citation Text

    Yuanming ZHAO, Bo ZHANG, Chengran ZHANG, Yafeng XIE, Qun NIU, Jinli TANG. Method of stray light suppression for annular folded aperture imaging system[J]. Infrared and Laser Engineering, 2024, 53(8): 20240189

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical design

    Received: May. 6, 2024

    Accepted: --

    Published Online: Oct. 29, 2024

    The Author Email: ZHANG Bo (zhangboyiran@163.com)

    DOI:10.3788/IRLA20240189

    Topics