Optical Instruments, Volume. 42, Issue 4, 47(2020)

Optical image quality comparison of three age-related human eye models

Ting YANG1...2,3, Xiaoli XU1,2,3, Xuedian ZHANG1,2,3, Feng LI1,2,3, and Minshan JIANG1,23,* |Show fewer author(s)
Author Affiliations
  • 1Shanghai Key Laboratory of Modern Optical System (MOE), University of Shanghai for Science and Technology, Shanghai 200093, China
  • 2Engineering Research Center of Optical Instrument and System, University of Shanghai for Science and Technology, Shanghai 200093, China
  • 3School of Optical-Electrical and Computer Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
  • show less
    Figures & Tables(11)
    Spot diagrams for the three eye models at different ages and different EPDs
    MTF diagrams for the three eye models at different ages and different EPDs
    Changes of SA and power vs age for the three eye models at different EPDs
    Spot diagrams for the two eye models with accommodation
    MTF diagrams for the two eye models with accommodation
    Changes of SA and power vs age for the two eye models with accommodation
    SA vs age with 5 mm pupil diameter
    • Table 1.

      The parameters changes in all models during accommodation

      调节过程中各模型眼的参数变化

      View table
      View in Article

      Table 1.

      The parameters changes in all models during accommodation

      调节过程中各模型眼的参数变化

      模型前房深度/mm晶状体厚度/mm晶状体前表面曲率半径/mm晶状体后表面曲率半径/mm
      调节前调节后调节前调节后调节前调节后调节前调节后
      Navarro模型3.6503.5903.4263.49811.0499.799−5.572−5.379
      Zapata-Díaz模型3.0763.0163.4263.49811.31410.159−5.895−5.708
    • Table 2.

      The change of vitreous thickness of each model after optimization

      各模型眼优化后玻璃体厚度的变化量

      View table
      View in Article

      Table 2.

      The change of vitreous thickness of each model after optimization

      各模型眼优化后玻璃体厚度的变化量

      年龄/岁玻璃体厚度变化量/mm
      Navarro模型Atchison模型Zapata-Díaz模型
      200.050.040.06
      400.090.070.11
      600.140.100.14
    • Table 3.

      The change of vitreous thickness after optimization of each model during accommodation

      调节期间各模型眼优化后玻璃体厚度的变化量

      View table
      View in Article

      Table 3.

      The change of vitreous thickness after optimization of each model during accommodation

      调节期间各模型眼优化后玻璃体厚度的变化量

      模型玻璃体厚度变化量/mm
      0.5 D1.0 D1.5 D2.0 D
      Navarro模型0.050.040.040.03
      Zapata-Díaz模型0.050.050.050.03
    • Table 4.

      The SR change rate of each model and clinical eye at different ages caused by the increase of age

      年龄增加导致的各模型眼和临床人眼在不同年龄段的SR变化率

      View table
      View in Article

      Table 4.

      The SR change rate of each model and clinical eye at different ages caused by the increase of age

      年龄增加导致的各模型眼和临床人眼在不同年龄段的SR变化率

      年龄/岁SR变化率/%
      Navarro 模型Atchison 模型Zapata-Díaz 模型真实人眼
      20~40−26.1−23.3−48.8−19.2
      40~60−29.4−24.2−52.4−23.8
    Tools

    Get Citation

    Copy Citation Text

    Ting YANG, Xiaoli XU, Xuedian ZHANG, Feng LI, Minshan JIANG. Optical image quality comparison of three age-related human eye models[J]. Optical Instruments, 2020, 42(4): 47

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: DESIGN AND RESEARCH

    Received: Feb. 1, 2020

    Accepted: --

    Published Online: Jan. 6, 2021

    The Author Email: JIANG Minshan (jiangmsc@gmail.com)

    DOI:10.3969/j.issn.1005-5630.2020.04.008

    Topics