Acta Optica Sinica, Volume. 33, Issue 4, 430006(2013)
Background Elimination Method Based on Harmonic Detection in No Absorption Spectral Region
[3] [3] Fan Fengying, Song Zengyun. Measurement of CO2 concentration with tunable diode laser absorption spectroscopy near 2 μm [J]. Chinese J. Lasers, 2012, 39(2): 0215002
[4] [4] Gao Nan, Du Zhenhui, Qi Rubin et al.. Data preprocessing of broad-spectrum tunable-diode-laser absorption spectroscopy [J]. Acta Optica Sinica, 2012, 32(4): 0430004
[5] [5] J. Gustafsson, N. Chekalin, O. Axner. Characterization of 2f-, 4f-, and 6f-background signals in wavelength modulation diode laser absorption spectrometry in graphite furnaces [J]. Spectrochimica Acta Part B, 2003, 58(1): 123~141
[6] [6] P. Kluczynski, O. Axner. Theoretical description based on Fourier analysis of wavelength- modulation spectrometry in terms of analytical and background signals [J]. Appl. Opt., 1999, 38(27): 5803~5815
[7] [7] K.Ruxton, A. L. Chakraborty, W. Johnstone et al.. Tunable diode laser spectroscopy with wavelength modulation: elimination of residual amplitude modulation in a phasor decomposition approach [J]. Sensors Actuators B, 2010, 150(1): 367~375
[8] [8] A. L. Chakraborty, K. Ruxton, W. Johnstone. Influence of the wavelength-dependence of fiber couplers on the background signal in wavelength modulation spectroscopy with RAM-nulling [J]. Opt. Express, 2010, 18(1): 267~280
[9] [9] L. Li, N. Arsad, G. Stewart et al.. Absorption line profile recovery based on residual amplitude modulation and first harmonic integration methods in photoacoustic gas sensing [J]. Opt. Commun., 2011, 284(1): 312~316
[10] [10] J. Reid, M. El-Sherbiny, B. K. Garside et al.. Sensitivity limits of a tunable diode laser spectrometer, with application to the detection of NO2 at the 100-ppt level [J]. Appl. Opt., 1980, 19(19): 3349~3354
[11] [11] J. A. Silver, A. C. Stanton. Optical interference fringe reduction in laser absorption experiments [J]. Appl. Opt., 1988, 27(10): 1914~1916
[12] [12] T. J. Johnson, F. G. Wienhold, J. P. Burrow et al.. Frequency modulation spectroscopy at 1.3 μm using InGaAsP lasers: a prototype field instrument for atmospheric chemistry research [J]. Appl. Opt., 1991, 30(4): 407~413
[13] [13] S.-Q. Wu, T. Kimishima, H. Kuze et al.. Efficient reduction of fringe noise in trace gas detection with diode laser multipass absorption spectroscopy [J]. Appl. Phys., 2000, 39(7A): 4034~4040
[14] [14] P. W. Werle, P. Mazzinghi, F. D′Amato et al.. Signal processing and calibration procedures for in situ diode-laser absorption spectroscopy [J]. Spectrochimica Acta Part A, 2004, 60(8-9): 1685~1705
[16] [16] L. Persson, F. Andersson, M. Andersson et al.. Approach to optical interference fringes reduction in diode laser absorption spectroscopy [J]. Appl. Phys. B, 2007, 87(3): 523~530
[17] [17] K. Duffin, A. J. McGettrick, W. Johnstone et al.. Tunable diode-laser spectroscopy with wavelength modulation: a calibration-free approach to the recovery of absolute gas absorption line shapes [J]. J. Lightwave Technol., 2007, 25(10): 3114~3125
Get Citation
Copy Citation Text
Zhang Rui, Zhao Xuehong, Hu Yajun, Guo Yuan, Liu Yanli, Wang Yan. Background Elimination Method Based on Harmonic Detection in No Absorption Spectral Region[J]. Acta Optica Sinica, 2013, 33(4): 430006
Category: Spectroscopy
Received: Dec. 10, 2012
Accepted: --
Published Online: Apr. 7, 2013
The Author Email: Rui Zhang (zhangrui@tust.edu.cn)