Journal of Innovative Optical Health Sciences, Volume. 8, Issue 3, 1541005(2015)

Multi-layered tissue head phantoms for noninvasive optical diagnostics

M. S. Wróbel1、*, A. P. Popov2, A. V. Bykov2, M. Kinnunen2, M. Jedrzejewska-Szczerska1, and V. V. Tuchin2,3,4
Author Affiliations
  • 1Department of Metrology and Optoelectronics Gdansk University of Technology Gabriela Narutowicza Street 11/12 80-233 Gdansk, Poland
  • 2Optoelectronics and Measurement Techniques Laboratory Faculty of Information Technology and Electrical Engineering University of Oulu, P. O. Box 4500 FI-90014 Oulu, Finland
  • 3Research-Educational Institute of Optics and Biophotonics Saratov State University, Saratov 410012, Russia
  • 4Institute of Precise Mechanics and Control Russian Academy of Sciences, Saratov 410028, Russia
  • show less

    Extensive research in the area of optical sensing for medical diagnostics requires development of tissue phantoms with optical properties similar to those of living human tissues. Development and improvement of in vivo optical measurement systems requires the use of stable tissue phantoms with known characteristics, which are mainly used for calibration of such systems and testing their performance over time. Optical and mechanical properties of phantoms depend on their purpose. Nevertheless, they must accurately simulate specific tissues they are supposed to mimic. Many tissues and organs including head possess a multi-layered structure, with specific optical properties of each layer. However, such a structure is not always addressed in the presentday phantoms. In this paper, we focus on the development of a plain-parallel multi-layered phantom with optical properties (reduced scattering coefficient μ's and absorption coefficient μa) corresponding to the human head layers, such as skin, skull, and gray and white matter of the brain tissue. The phantom is intended for use in noninvasive diffuse near-infrared spectroscopy (NIRS) of human brain. Optical parameters of the fabricated phantoms are reconstructed using spectrophotometry and inverse adding-doubling calculation method. The results show that polyvinyl chloride-plastisol (PVCP) and zinc oxide (ZnO) nanoparticles are suitable materials for fabrication of tissue mimicking phantoms with controlled scattering properties. Good matching was found between optical properties of phantoms and the corresponding values found in the literature.

    Tools

    Get Citation

    Copy Citation Text

    M. S. Wróbel, A. P. Popov, A. V. Bykov, M. Kinnunen, M. Jedrzejewska-Szczerska, V. V. Tuchin. Multi-layered tissue head phantoms for noninvasive optical diagnostics[J]. Journal of Innovative Optical Health Sciences, 2015, 8(3): 1541005

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Mar. 3, 2014

    Accepted: Jun. 17, 2014

    Published Online: Jan. 10, 2019

    The Author Email: Wróbel M. S. (maciejswrobel@gmail.com)

    DOI:10.1142/s1793545815410059

    Topics