High Power Laser and Particle Beams, Volume. 32, Issue 3, 035003(2020)

Study on temperature rise of electromagnetic coil launcher

Min Xiong1... Yadong Zhang1, Yujia Gong2 and Hu Zhang2 |Show fewer author(s)
Author Affiliations
  • 1School of Electrical and Automation Chemistry, Wuhan University, Wuhan 430072, China
  • 2China Electric Power Research Institute Co Ltd, Wuhan 430074, China
  • show less
    Figures & Tables(15)
    Lumped parameter model of class k synchronous induction coil transmitter
    single stage electromagnetic induction coil transmitter model and corresponding parameters
    Temperature rise of coil and armature and armature speed curve
    Calculation results of motion field of coil launcher
    Single-stage coil emitter results (t= 0.016 s)
    Temperature variation of a specific unit over time
    Test capacitor discharge circuit diagram
    Temperature acquisition section
    Layout of temperature sensors
    Arrangements and photo of coil temperature sensors
    Pulse discharge waveforms
    Model temperature measurements
    • Table 1. Electromagnetic induction coil launcher parameters

      View table
      View in Article

      Table 1. Electromagnetic induction coil launcher parameters

      internal diameter/mmthickness/mmlength/mmturnsinternal diameter/mmlength/mmcapacitance/mFvoltage/V
      armaturecoilpower supply
      37.51010026606021 300
    • Table 2. Comparison of single stage electromagnetic induction coil transmitter results

      View table
      View in Article

      Table 2. Comparison of single stage electromagnetic induction coil transmitter results

      methodcomsol multiphysical field simulationcurrent wire model method
      outlet velocity/(m·s-1) 8.2868.827
      maximum speed/(m·s-1) 8.5699.644
      maximum coil temperature/℃(t=0.016 s) 28.0328.29
      armature maximum temperature/℃(t=0.016 s) 24.1024.23
      maximum coil temperature/℃(whole process)28.0528.29
      armature maximum temperature/℃(whole process)25.4124.23
    • Table 3. Single pulse discharge test results of single-stage induction coil transmitter (t=100 s)

      View table
      View in Article

      Table 3. Single pulse discharge test results of single-stage induction coil transmitter (t=100 s)

      test temperature/℃simulation temperature/℃error/%
      armature tail outer side13.8513.9260.55
      inside armature tail13.7813.860.58
      1 cm from armature tail13.9113.9470.27
      coil wire17.2518.386.1
    Tools

    Get Citation

    Copy Citation Text

    Min Xiong, Yadong Zhang, Yujia Gong, Hu Zhang. Study on temperature rise of electromagnetic coil launcher[J]. High Power Laser and Particle Beams, 2020, 32(3): 035003

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Aug. 15, 2019

    Accepted: --

    Published Online: Mar. 19, 2020

    The Author Email:

    DOI:10.11884/HPLPB202032.190300

    Topics